Chapter 3 Component Status
3.24 Port Detail
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED
P2X0-1260-19ENZ0
189
-
Redundancy
The connection type of the port is displayed. When the connection type is "Active-Active" or "Active-
Standby", the "Redundant Port" information is displayed.
•
Active-Active
Combine the ports in both of the CMs and configure the redundant ports. For this configuration, the
ports of both CMs can be used at any time.
•
Active-Standby
Combine the ports in both of the CMs and configure the redundant ports. For this configuration, one
port remains in standby status.
•
Single
Use only for the ports in the CM that are not redundant.
-
Redundant Port
The installation locations of the ports that are configured for redundancy with the target port are
displayed. When redundancy is configured for each bonding port, all of the related ports are displayed.
A "-" (hyphen) is displayed when "Redundancy" is "Single".
•
CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
-
Failover Status
The failover status of the multipath is displayed.
A "-" (hyphen) is displayed when the multipath is not set (or when "Redundancy" is "Single").
•
Normal
The multipath setting between the "Location" port and "Redundant Port" is in a normal state.
•
CM#x CA#y Port#z is currently inactive
The multipath between the "Location" port and "Redundant Port" is set, but the "CM#x CA#y Port#z"
port is not used.
-
Port Bonding Mode
The bonding mode for the port is displayed.
•
Master
The representative port among the ports that configure the bonding port. The IP address of the
bonding port is assigned to the master port.
•
Member
Ports that configure the bonding port.
-
Bonding Master Port
The installation location of the master port, which is a member of the ports that configure the bonding
port, is displayed.
If the bonding port is not configured, a "-" (hyphen) is displayed.
•
CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
-
Bonding Port
The installation locations of all the member ports that configure the bonding port is displayed.
If the bonding port is not configured, a "-" (hyphen) is displayed.
•
CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
-
Number of VLAN IP Addresses
The number of VLAN IP addresses for the port is displayed.
If VLAN is not set, "0" is displayed.