Chapter 7 Thin Provisioning Pool Status
7.3 Settings (Thin Provisioning)
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED
P2X0-1260-19ENZ0
355
7.3
Settings (Thin Provisioning)
This function displays information on the Thin Provisioning function settings.
The following items are displayed in the Main area:
•
Thin Provisioning
Whether the Thin Provisioning function is enabled or disabled is displayed.
•
Maximum Pool Capacity
The maximum pool capacity that is specified for the ETERNUS DX/AF is displayed.
The maximum pool capacity is the maximum total capacity for TPPs and FTRPs that can be created in the
ETERNUS DX/AF. This item is displayed only when "Enable" is selected for the Thin Provisioning function.
-
ETERNUS DX60 S3
32.00 TB, 64.00 TB, 128.00 TB
-
ETERNUS DX100 S3/DX200 S3
32.00 TB, 64.00 TB, 128.00, 256.00 TB
-
ETERNUS DX500 S3
64.00 TB, 128.00 TB, 256.00 TB, 384.00 TB
-
ETERNUS DX600 S3
128.00 TB, 256.00 TB, 512.00 TB, 768.00 TB, 1024.00 TB
-
ETERNUS DX8100 S3
64.00 TB, 128.00 TB
-
ETERNUS DX8700 S3/DX8900 S3
256.00 TB, 512.00 TB, 768.00 TB, 1024.00 TB, 1536.00 TB, 2048.00 TB
-
ETERNUS AF250
32.00 TB, 64.00 TB, 128.00 TB, 256.00 TB
The parameters that are described below can be changed. Refer to "Set Thin Provisioning" in "ETERNUS Web
GUI User’s Guide (Settings)" for details.
•
Whether to enable or disable the Thin Provisioning function
•
Maximum Pool Capacity