Appendix C Setting Procedures for Replacing HBAs
C.3 Checking the Connection Status Between the Host and the ETERNUS DX/AF
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED
P2X0-1260-19ENZ0
417
C.3
Checking the Connection Status Between the Host and the
ETERNUS DX/AF
Perform the following procedure to check the connection status between the host and the ETERNUS DX/AF.
Procedure
1
Click [Connectivity] in the navigation.
2
Click [FC/FCoE] in the category.
The [FC/FCoE Host] screen appears.
3
Check the connection status between the relevant host and the ETERNUS DX/AF in the
"Status" field.
■
When the host affinity settings are used
"Active" is displayed as the status. Proceed to
"C.4 Required Storage System Settings After HBA
Replacement (When Host Affinity Settings are Used)" (page 418)
■
When the host affinity settings are not used (conventional LUN mapping is used)
"Inactive" is displayed as the status. In this case, settings after replacing the HBA are not required.
The replacement of the HBA is complete.
End of procedure