Setup Audit Log
This function sets up external servers (Syslog servers) for sending audit logs that are detected by the ETERNUS
DX.
Up to two Syslog servers can be registered.
For details on the parameters for this function, refer to
"A.1.9.1 Setup Audit Log" (page 750)
.
For the factory default settings for this function, refer to
"Appendix B Setup Audit Log" (page 983)
.
The procedure to set up the servers for sending audit logs is as follows:
Procedure
1
Click [Setup Audit Log] in [Action].
•
Enable the "Audit Log" setting, and then configure the destination Syslog server. Audit logs are sent after
the Syslog server is specified.
•
Confirm that the audit log has been successfully sent to the Syslog server by logging in and out from
ETERNUS Web GUI or ETERNUS CLI and performing a transmission test to the Syslog server.
•
Even if a communication error occurs between the ETERNUS DX and the Syslog server, the audit log is not
sent again.
•
Changing the Syslog server setting is only available when the "Audit Log" setting is "Enable". Note that
once "on" is selected for the "Send Audit Log" setting, the "Send Audit Log" setting cannot be changed to
"off" for both of the Syslog servers (at least one Syslog server must be "on").
•
The audit log function uses the destination server that has the same interface as the Syslog server. The
same server as the Syslog server is also available.
•
The audit logs are sent to both Syslog servers at the same time.
•
Even if the "Audit Log" setting changed to "Disable", the audit log setting information in the ETERNUS DX
is maintained.