Chapter 3 Configuration Settings and Display
3.5 Host Interface Management > set iscsi-parameters
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
215
■
Example(s)
-rec-transfer-sync
Optional. This parameter specifies the synchronous mode for the copy transfer mode. If
omitted, the existing setting is not changed. This parameter can be specified only when the RA
mode or CA/RA auto mode is used.
enable
An REC in synchronous transfer mode is permitted for the target CA port.
disable
An REC in synchronous transfer mode is suppressed for the target CA port.
-rec-transfer-stack
Optional. This parameter specifies the asynchronous stack mode for the copy transfer mode. If
omitted, the existing setting is not changed. This parameter can be specified only when the RA
mode or CA/RA auto mode is used.
enable
An REC in asynchronous stack mode is permitted for the target CA port.
disable
An REC in asynchronous stack mode is suppressed for the target CA port.
-rec-transfer-consistency
Optional. This parameter specifies the asynchronous consistency mode for the copy transfer
mode. If omitted, the existing setting is not changed. This parameter can be specified only
when the RA mode or CA/RA auto mode is used.
enable
An REC in asynchronous consistency mode is permitted for the target CA port.
disable
An REC in asynchronous consistency mode is suppressed for the target CA port.
-rec-transfer-through
Optional. This parameter specifies the asynchronous through mode for the copy transfer mode.
If omitted, the existing setting is not changed. This parameter can be specified only when the
RA mode or CA/RA auto mode is used.
enable
An REC in asynchronous through mode is permitted for the target CA port.
disable
An REC in asynchronous through mode is suppressed for the target CA port.
The following example disables Host Affinity Mode for iSCSI interface port#0 on CM#1 CA#0:
CLI> set iscsi-parameters -port 100 -host-affinity disable
The following example sets "192.168.1.1" for the IP address, "255.255.255.0" for the subnet mask, and
"user01" for the CHAP user name of iSCSI interface port#1 on CM#0 CA#1:
CLI> set iscsi-parameters -port 001 -ip 192.168.1.1 -netmask 255.255.255.0 -chap-user user01
Password :
Confirm Password :
The following example enables the jumbo frame function on all iSCSI interface ports:
CLI> set iscsi-parameters -port all -jumbo-frame enable