Chapter 3 Configuration Settings and Display
3.5 Host Interface Management > set host-sense
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
300
set host-sense
This parameter specifies the preset host sense corresponding to the specific host operating system.
■
Syntax
■
Parameter
set host-sense
{-host-response-number
host_response_numbers
| -host-response-name
host_response_names
}
-preset {no-conversion | linux | windows|custom}
[-original-sk
original_sk
] [-original-asc
original_asc
] [-original-ascq
original_ascq
]
[-converted-sk
converted_sk
] [-converted-asc
converted_asc
]
[-converted-ascq
converted_ascq
]
-host-response-number
or
-host-response-name
This parameter specifies the host response identifier that is to be used to set the host sense.
One or more parameters can be specified. For details, refer to
.
-preset
This parameter specifies the preset host sense corresponding to the specific host operating
system.
no-conversion
It will revert to the default host sense value (Default).
linux
Linux host (when Linux GRMPD is not in use).
windows
Windows host (when GR/ETERNUS MPD and its device driver are not in use).
custom
Custom setting. The following sense parameters can be specified only when this
setting is selected.
-original-sk Optional. This parameter specifies the sense key that corresponds to the sense of the
conversion source. This parameter can only be specified when "-preset custom" is selected. This
parameter must be specified by using either a hexadecimal number or the wildcard (*).
-original-asc
Optional. This parameter specifies the sense code, which is an additional sense code, that
corresponds to the sense of the conversion source. This parameter can only be specified when
"-preset custom" is selected. This parameter must be specified by using either a hexadecimal
number or the wildcard (*).
-original-ascq
Optional. This parameter specifies the sub sense code, which is an additional sense code
qualifier that corresponds to the sense of the conversion source. This parameter can only be
specified when "-preset custom" is selected. This parameter must be specified by using either a
hexadecimal number or the wildcard (*).