Chapter 4 Function/System Settings and Display
4.2 Advanced Copy Management > measure rec-round-trip-time
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
433
■
Output
■
Example(s)
When the "manual" mode is selected:
# Remote Box ID Round Trip Time(ms)
# 00DXL#########ET06F21AUABCPJ000002###### 20
A B
A:
Box ID of a remote storage system
B
A measured round trip time
The following example measures the round trip times to all remote storage systems for which a round trip
time has not yet been set, and automatically reflects this to the system. remote storage systems for which a
round trip time has already been set are not remeasured or otherwise affected.
CLI> measure rec-round-trip-time -mode auto
The following example displays the measured round trip time, and confirms with the operator whether or
not the result is to be saved to the system. In this example, the measured round trip time is reflected to the
system.
CLI> measure rec-round-trip-time -mode manual -remote-boxid "00DXL#########ET06F21AUAB-
CPJ000002######"
Remote Box ID Round Trip Time(ms)
00DXL#########ET06F21AUABCPJ000002###### 20
Enter 'y' to save this round trip time or 'n' to cancel.
> y
Complete.
The following example is the same as the above except entering a cancel. In this case, the round trip time is
not reflected to the system.
CLI> measure rec-round-trip-time -mode manual -remote-boxid "00DXL#########ET06F21AUAB-
CPJ000002######"
Remote Box ID Round Trip Time(ms)
00DXL#########ET06F21AUABCPJ000002###### 20
Enter 'y' to save this round trip time or 'n' to cancel.
> n
Canceled.