Chapter 4 Function/System Settings and Display
4.3 Network Management > set event-notification
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
516
-severity
This parameter specifies the events that will trigger a notification and cannot be specified if
the preset function is specified. An operand name starting with "e-" indicates a severity "Error
level" event, "w-" indicates a severity "Warning level" event, and "i-" indicates a severity
"Information level event". One or more event types can be specified by separating them with a
comma.
Example: -severity error, w-warning-disk (Specify "error" and "w-warning-disk")
"-suppression disable-when-no-hs" indicates whether the specified event is notified or not
when there is no hot spare in the system. It can be specified when "e-broken-disk", "e-rebuild-
copyback-without-redundant", " e-redundant", "w-warning-disk", or "w-raid-degrade-event" is
specified.
error
All the Error level events are notified.
warning
All the Warning level events are notified.
information All the Information level events are notified.
e-parts-error
When modules other than disks are broken, error level events are notified. Host
sense, SNMP, E-mail, and syslog may be specified as the notice method.
e-disk-error When a disk is broken, error level events are notified. Host sense, SNMP, E-mail,
and syslog may be specified as the notice method.
e-temperature-error
When the sensor detects an error level temperature, error level events are
notified. Host sense, SNMP, E-mail, and syslog may be specified as the notice
method.
e-battery-life
When battery life expires, error level events are notified. Host sense, SNMP, E-
mail, and syslog may be specified as the notice method. (only for the ETERNUS
DX410 S2/DX440 S2 and ETERNUS DX8100 S2/DX8700 S2)
e-rebuild-copyback-with-redundant
When rebuild/copyback occurs to a RAID group with redundancy, error level
events are notified. Only Host sense may be specified as the notice method. Any
notice method may be specified.
e-rebuild-copyback-without-redundant
When rebuild/copyback occurs to a RAID group without redundancy, error level
events are notified. Only Host sense may be specified as the notice method. Any
notice method may be specified.
e-complete-redundant-copy
When the redundant copy is complete, error level events are notified. Any notice
method may be specified.
e-complete-rebuild
When rebuild is finished, error level events are notified. Host sense, SNMP, e-
mail, and syslog may be specified as the notice method.
e-bad-data When bad data on a track occurs, error level events are notified. Host sense,
SNMP, e-mail, and syslog may be specified as the notice method.
e-pinned-data
When pinned data occurs or disappears, error level events are notified. Host
sense, SNMP, e-mail, and syslog may be specified as the notice method. Note
that, however, host sense is not used as the notification method when pinned
data disappears.
Summary of Contents for Eternus DX410 S2
Page 2: ...This page is intentionally left blank ...
Page 756: ......