Chapter 4 Function/System Settings and Display
4.3 Network Management > set event-notification
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
517
e-not-ready When Not-Ready occurs, error level events are notified. Host sense, SNMP, E-
mail, and syslog may be specified as the notice method.
e-remote-path
When REC path(s) are in an error condition, error level events are notified. Any
notice method may be specified.
e-halt-path When REC path(s) are halted due to a path(s) error, error level events are
notified. SNMP, E-mail, and REMCS may be specified as the notice method.
e-halt-overload
When REC path(s) are halted due to line overload, error level events are notified.
SNMP, E-mail, and REMCS may be specified as the notice method.
e-halt-other When REC path(s) are halted due to another cause, error level events are
notified. SNMP, E-mail, and REMCS may be specified as the notice method.
e-tp-pool-ratio
When the transition of the thin provisioning pool ratio increases, error level
events are notified. SNMP, E-mail and syslog may be specified as the notice
method.
e-redundant When the redundant copy starts or ends, error level events are notified. Any
notice method may be specified.
e-sed-network-error
When network connection errors occur with the key server, error level events are
notified. SNMP, E-mail, REMCS, syslog, and AIS Connect may be specified as the
notice method.
e-copy-session-error
When an error occurs for a copy session or an abnormal copy session disappears,
error level events are notified. SNMP, E-mail, REMCS, and syslog may be specified
as the notice method.
w-parts-warning
When other modules are in a warning condition, warning level events are
notified. Host sense, SNMP, E-mail and syslog may be specified as the notice
method.
w-disk-warning
When disks are in a warning condition, warning level events are notified. Host
sense, SNMP, E-mail and syslog may be specified as the notice method.
w-temperaturewarning
When the sensor detects warning level temperature, warning level events are
notified. Host sense, SNMP, E-mail, and syslog may be specified as the notice
method.
w-battery-life
When battery life will soon expire, warning level events are notified. Host sense,
SNMP, E-mail, and syslog may be specified as the notice method. (only for the
ETERNUS DX410 S2/DX440 S2 and ETERNUS DX8100 S2/DX8700 S2)
i-recovery-module
When parts are recovered, information level events are notified. Host sense,
SNMP, E-mail, and syslog may be specified as the notice method. When reset
groups for host ports are set, only SNMP and E-mail may be specified as the
notice method.