Chapter 4 Function/System Settings and Display
4.4 Miscellaneous > show power-synchronization
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
575
■
Example(s)
K:
The signal polarity that controls the UPS output stop signal when the shutdown is complete (This item is
displayed only for the ETERNUS DX80 S2/DX90 S2).
L:
It shows whether the UPS output stop signal is enabled or not when the shutdown is complete (This item is
displayed only for the ETERNUS DX80 S2/DX90 S2).
The following example displays the settings that control how the shutdown function interacts with the
external sensor (for the ETERNUS DX80 S2/DX90 S2):
CLI> show power-synchronization
Controller Module #0 Enable
Controller Module #1 Disable
Auto Power Enable
Resume Power Disable
Waiting Time to Shutdown 5 min.
Type Power Synchronized Unit
Power Fail Signal Positive
Low Battery Signal Negative
UPS Shutdown Signal Negative
UPS Shutdown Enable
The following example displays the settings that control how the shutdown function interacts with the
external sensor (for the ETERNUS DX410 S2/DX440 S2):
CLI> show power-synchronization
Controller Module #0 Enable
Controller Module #1 Disable
Auto Power Enable
Resume Power Disable
The following example displays the settings that control how the shutdown function interacts with the
external sensor (for the ETERNUS DX8700 S2):
CLI> show power-synchronization
Service Controller #0 Enable
Service Controller #1 Disable
Auto Power Enable
Resume Power Disable