Chapter 2 Status Display
2.1 Storage System Status > show fru-de
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
63
■
Example(s)
DE#n IOM#m Internal Parts Status/Status Code
SAS Cable #0(IN) (IOM Port #0)
SAS Cable #0(IN)(IOM port #0) status and the status code
Error Code
Error code to identify error events that have occurred in port#0
This information is only displayed when the Status is not "Normal" or "Undefined".
SAS Cable #1(IN) (IOM Port #1)
SAS Cable #1(OUT)(IOM port #1) status and the status code
Error Code
Error code to identify error events that have occurred in that port#1
The following table shows the output information for the power supply units.
Status/Status Code
Power supply unit (PSU#n) status and the status code
Error Code
Error code to identify error events that occurred in a power supply unit
This information is only displayed when the Status is not "Normal" or "Undefined".
The following example displays the status of I/O module #0 in drive enclosure #1:
CLI> show fru-de -de 1 -type iom0
DE#1 IOM#0 Information
Status/Status Code [Normal / 0xE001]
WWN [500000E0D060C4FF]
Active EC [EC#1]
Next EC [EC#1]
DE#1 IOM#0 Internal Parts Status/Status Code
SAS Cable(Expander Port)#0(IN) [Normal / 0xE001]
SAS Cable(Expander Port)#1(OUT) [Normal / - ]
The following example displays the status of PSU#0 in drive enclosure #2:
CLI> show fru-de -de 2 -type psu0
DE#2 PSU#0 Information
Status/Status Code [Normal / 0xE001]