Chapter 5 Information Settings and Display
5.3 Maintenance > show disk-error
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
650
show disk-error
This command displays the details of disk errors.
■
Syntax
■
Parameter
No parameters.
■
Output
■
Example(s)
show disk-error
# E Disk Status Port Media Drive Drive-Recovered SMART I/O Link Check-Code
# Location Error Error Error Error Timeout Error Error
# * CE-Disk#0 Rebuild/Copyback Port#0 0 0 0 0 0 0 0
# A B C Port#1 0 0 0 0 0 0 1
D E F G H I J K
A:
An error Sign (*), it shows there are some errors of both ports.
B:
Disk Number
C:
Disk status
D:
Disk Port Number
E:
Media Error Count
F:
Drive Error Count
G:
Drive Recovered Error Count
H:
SMART Event Count
I:
I/O Timeout Count
J:
Link Error Count
K:
Check Code Error Count
The following example displays the disk error information:
CLI> show disk-error
E Disk Status Port Media Drive Drive-Recovered SMART I/O Link Check-Code
Location Error Error Error Error Timeout Error Error
* CE-Disk#0 Rebuild/Copyback Port#0 0 0 0 0 0 0 0
Port#1 0 0 0 0 0 0 1
* CE-Disk#1 Available(Predictive Failure) Port#0 2 0 0 1 0 0 0
Port#1 0 0 0 0 0 0 0
DE#4-Disk#0 Rebuild/Copyback Port#0 0 0 0 0 0 0 0
Port#1 0 0 0 0 0 0 0