Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
360
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
•
Alias Name
Enter the alias name of the target port.
While the iSCSI name is a formal nomenclature that specifies the target iSCSI port, an
alias name is used as nickname.
An alias name that is the same as another port cannot be specified.
The following input condition applies:
-
1 - 31 alphanumeric characters
●
General Settings
•
Jumbo Frame
Select whether to "Enable" or "Disable" the Jumbo Frame.
Select "Enable" when using the Jumbo Frame to transfer data via the target port. When
not using the Jumbo Frame, select "Disable".
Enabling Jumbo Frame increases the amount of data to be transferred per Frame,
making data transfer more efficient.
Confirm that the connected device (*1) supports the Jumbo Frame before enabling the
Jumbo Frame.
*1:
When the ETERNUS DX Disk storage system and server are connected directly, this
indicates that the connected device is a server side LAN card (NIC). When the ETERNUS
DX Disk storage system and server are connected via a switch, this indicates that the
connected device is a switch.
•
VLAN_ID
Select whether to use a manually specified VLAN ID ("Fixed") or an automatically spec-
ified VLAN ID ("Auto").
When "Fixed" is selected, enter the VLAN ID between 0 and 4095.
•
Reset Scope
Specify the reset scope of the target port.
Reset scope is the range where the command reset request from the server is
performed, when the target port is connected to multiple servers.
-
I_T_L (I: Initiator, T: Target, L: LUN)
Reset (cancel) the command request from the server that sent the command reset
request.
-
T_L (T: Target, L: LUN)
Reset (cancels) the command request from all of the servers that are connected to
the port.
•
Release Reservation if Chip is Reset
Select whether to "Enable" or "Disable" the function to release the reserved status of
the volume when the target port (chip) is reset.
An iSCSI name is a unique name in the ETERNUS DX Disk
storage system. The same iSCSI name cannot be set to multiple
iSCSI ports except the device iSCSI name.
When specifying the VLAN_ID, confirm the VLAN setting values
of the LAN switch and the tag VLAN settings of the server LAN
card.