Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
553
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
•
Thin Provisioning Pool Rate
Select whether to notify when the TPP usage changes (*1). When notifying, select the
notification method.
*1:
Notify when the TPP usage changes as follows:
-
From "Normal" to "Attention"
-
From "Normal" or "Attention" to "Warning"
-
The TPP capacity is exhausted
●
Warning Severity Level
Select whether to notify of a warning event for each event type.
•
Parts Warning
Select whether to notify when a warning level event occurs in a component other than
the drive. When notifying, select the notification method.
•
Disk Warning
Select whether to notify when a warning level event occurs in the drive for each condi-
tion shown below. When notifying, select the notification method.
-
Any Time
Notifies always when a warning level event occurs in the drive.
-
when HS<0
Notifies only when a warning level event occurs in the drive while available hot
spare disk is "Less than 0" (*1).
*1:
When rebuilding cannot be performed because there are no hot spares that can be
used as a substitute for the failed drive.
•
Temperature Warning
Select whether to notify when a temperature warning status is detected by the sensor.
When notifying, select the notification method.
•
Battery life Warning
Select whether to notify a battery expiration in advance (*1). When notifying, select the
notification method.
"Battery life Warning" notification is available only for ETERNUS DX410 S2/DX440 S2.
*1:
Advance notice of battery expiration is issued once "6 months before", once "a week
before", and once a day during the period from "6 days before" to "the expiration date".
•
Blink Fault LED at warning
Select "Enable" when setting the Fault LED in the front panel to blink while a warning
level event occurs, and select "Disable" when setting the Fault LED not to blink.
•
Turn on Fault LED when redundant copy is complete
Select "Enable" when setting the Fault LED of the drive to turn on while a warning level
event occurs, and select "Disable" when setting the Fault LED not to turn on.
●
Informational Level
Select whether to notify of an informational event for each event type.
•
Recovery module
Select whether to notify when the failed component is recovered by taking actions such
as replacement. When notifying, select the notification method.