background image

Summary of Contents for ETERNUS2000 100

Page 1: ......

Page 2: ......

Page 3: ...900 1100 1200 2100 or 2200 Disk storage system server OS used Fibre Channel cards drivers etc Note that this manual refers the following documents Server Support Matrix ETERNUS Disk storage systems Server Connection Guide Fibre Channel for Oracle Solaris Also note that in this document the ETERNUS2000 models 100 and 200 ETERNUS4000 models 300 400 500 and 600 and ETERNUS8000 models 700 800 900 1100...

Page 4: ...nd Java are registered trademarks of Oracle and or its affiliates All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the United States and other countries The company names product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies Naming Conventions Product name...

Page 5: ...5 Reconfiguring and Restarting the Server 10 3 1 6 Checking the MPxIO Multipath Status 11 3 2 Solaris 9 OS 12 3 2 1 Disabling MPxIO on Some Paths 12 3 2 2 Checking the Storage System Status 13 3 2 3 Editing the kernel drv scsi_vhci conf Settings 13 3 2 4 Reconfiguring and Restarting the Server 14 3 2 5 Checking the MPxIO Multipath Status 15 3 3 Solaris 8 OS 16 3 3 1 Disabling MPxIO on Some Paths 1...

Page 6: ... drv fp conf Specify any devices that will not form part of the multipath connection Solaris 10 OS 3 1 Solaris 10 OS page 8 Solaris 9 OS 3 2 Solaris 9 OS page 12 Solaris 8 OS 3 3 Solaris 8 OS page 16 Change Settings kernel drv fp conf kernel drv scsi_vhci conf 1 Enable multipathing 2 Enable the auto failback function Change Settings kernel drv scsi_vhci conf 1 Enable multipathing 2 Enable the auto...

Page 7: ...Server Connection Guide Fibre Channel for Oracle Solaris and the Server Support Matrix MPxIO is bundled with Solaris 10 OS from Update 1 onwards so separate installation is not required for these versions Download and install the Sun StorEdge SAN MPxIO software from the following Oracle web site for Solaris 10 OS Solaris 9 OS and Solaris 8 OS Refer to the Oracle web site for more details http www ...

Page 8: ...ath function is not necessary when multipathing is to be set up for all the LUNs that are recognized by the OS In these cases proceed to 3 1 2 Enabling MPxIO page 9 Procedure 1 Use the cat command etc to check the etc path_to_inst file and identify the physical pathname of the device for which multipathing is not required In this example the physical path is pci 8 600000 SUNW qlc 2 2 Add the follo...

Page 9: ...le yes mpxio disable no Global mpxio disable property To globally enable MPxIO on all fp ports set mpxio disable no To globally disable MPxIO on all fp ports set mpxio disable yes mpxio disable no Example Comment out this line Add this line format Searching for disks done AVAILABLE DISK SELECTIONS 0 c1t0d0 SUN146G cyl 14087 alt 2 hd 24 sec 848 pci 8 600000 SUNW qlc 2 fp 0 0 ssd w500000e0113ce2e1 0...

Page 10: ...nc All rights reserved Use is subject to license terms pragma ident scsi_vhci conf 1 9 04 08 26 SMI name scsi_vhci class root Load balancing global configuration setting load balance none will cause all I O to a given device which supports multipath I O to occur via one path Setting load balance round robin will cause each path to the device to be used in turn load balance round robin Automatic fa...

Page 11: ...t 2 hd 64 sec 256 scsi_vhci ssd g6000b5d0006a0000006a010900000000 c2 and c3 paths changed to c7 path making a multipath configuration luxadm display dev rdsk c7t6000B5D0006A0000006A010900000000d0s2 DEVICE PROPERTIES for disk dev rdsk c7t6000B5D0006A0000006A010900000000d0s2 Vendor FUJITSU Product ID E8000 Revision 0000 Serial Num 6A0109 Unformatted capacity 10240 000 MBytes Write Cache Enabled Read...

Page 12: ...Status page 13 Procedure 1 Use the cat command etc to check the etc path_to_inst file and identify the physical pathname of the device for which multipathing is not required In this example the physical path is pci 8 600000 SUNW qlc 2 2 Add the following line to the kernel drv fp conf file using the vi command Example End of procedure If this setting is omitted multipathing is set up for all LUNs ...

Page 13: ...IO Otherwise add this line or change its value to no 2 Enable the auto failback function Check that an auto failback enable line exists enabling the auto failback function Otherwise add this line or change its value to enable format Searching for disks done AVAILABLE DISK SELECTIONS 0 c1t0d0 SUN146G cyl 14087 alt 2 hd 24 sec 848 pci 8 600000 SUNW qlc 2 fp 0 0 ssd w500000e0113ce2e1 0 1 c2t2051000B5...

Page 14: ...ing load balance none will cause all I O to a given device which supports multipath I O to occur via one path Setting load balance round robin will cause each path to the device to be used in turn load balance round robin Force load driver to support hotplug activity do not remove this property ddi forceattach 1 Automatic failback configuration possible values are auto failback enable or auto fail...

Page 15: ...t 2 hd 64 sec 256 scsi_vhci ssd g6000b5d0006a0000006a010900000000 c2 and c3 paths changed to c7 path making a multipath configuration luxadm display dev rdsk c7t6000B5D0006A0000006A010900000000d0s2 DEVICE PROPERTIES for disk dev rdsk c7t6000B5D0006A0000006A010900000000d0s2 Vendor FUJITSU Product ID E8000 Revision 0000 Serial Num 6A0109 Unformatted capacity 10240 000 MBytes Write Cache Enabled Read...

Page 16: ...Status page 17 Procedure 1 Use the cat command etc to check the etc path_to_inst file and identify the physical pathname of the device for which multipathing is not required In this example the physical path is pci 8 600000 SUNW qlc 2 2 Add the following line to the kernel drv fp conf file using the vi command Example End of procedure If this setting is omitted multipathing is set up for all LUNs ...

Page 17: ...s line or change its value to enable 3 Enable the Symmetric option Add the following line For the ETERNUS2000 For the ETERNUS4000 For the ETERNUS8000 format Searching for disks done AVAILABLE DISK SELECTIONS 0 c1t0d0 SUN146G cyl 14087 alt 2 hd 24 sec 848 pci 8 600000 SUNW qlc 2 fp 0 0 ssd w500000e0113ce2e1 0 1 c2t2051000B5D6A0109d0 FUJITSU E8000 0000 cyl 6248 alt 2 hd 64 sec 256 pci 9 600000 SUNW ...

Page 18: ...h I O to occur via one path Setting load balance round robin will cause each path to the device to be used in turn load balance round robin Force load driver to support hotplug activity do not remove this property ddi forceattach 1 Automatic failback configuration possible values are auto failback enable or auto failback disable This functionality requires patch 113039 02 or higher auto failback e...

Page 19: ...2 hd 64 sec 256 scsi_vhci ssd g6000b5d0006a0000006a010900000000 c2 and c3 paths changed to c7 path making a multipath configuration luxadm display dev rdsk c7t6000B5D0006A0000006A010900000000d0s2 DEVICE PROPERTIES for disk dev rdsk c7t6000B5D0006A0000006A010900000000d0s2 Vendor FUJITSU Product ID E8000 Revision 0000 Serial Num 6A0109 Unformatted capacity 10240 000 MBytes Write Cache Enabled Read C...

Page 20: ...ted without notice While the contents of this manual are the product of all due care and diligence no responsibility can be accepted for operational problems arising from any errors or missing information or other use of the information contained in this manual Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual ...