Humidistat
Typical
Two-Stage
Thermostat
Heat Pump
Outdoor
Unit
Field Installed
Line Voltage
-
WIRING INFORMATION
Factory Standard
-
W1
C
G
Air Handler
Y2
ODD
R
Y1
B
W2
E/W1
C
G
R
Y1
B
W2
Y2
B
D
Y1
R
BL
Y
Y/BL
R
W/R
BR
PR
C
L
FIGURE 9
TYPICAL THERMOSTAT: STD COOLING W / ELECTRIC HEAT
Single-Stage
A/C Thermostat
A/C Outdoor Unit
G
Field Installed
Line Voltage
-
WIRING INFORMATION
Factory Standard
-
Y
C
W/BL
W1
G
Air Handler
B
ODD
R
Y
W2
G/BK
Y
W/BK
G/Y
BR
R
BL
R
Y
W
C
C
Humidistat
FIGURE 10
TYPICAL THERMOSTAT: STD COOLING W / ELECTRIC HEAT USING A
HUMIDISTAT FOR DEHUMIDIFICATION
C
Y2
Two Stage
A/C Thermostat
A/C Outdoor Unit
G
Field Installed
Line Voltage
-
WIRING INFORMATION
Factory Standard
-
D
Y
C
W/BL
W1
G
Air Handler
ODD
R
Y
B
W2
G/BK
Y
W/BK
G/Y
BR
R
R
Y
W2
W
C
BL
*
FIGURE 11
TYPICAL THERMOSTAT: STD COOLING W / ELECTRIC HEAT USING A
2-STG DEHUMIDIFYING THERMOSTAT
C
Heat Pump
Thermostat
Heat Pump
Outdoor Unit
D
B
G
Field Installed
Line Voltage
-
WIRING INFORMATION
Factory Standard
-
B
E
Y
R
C
R
W1
C
G
Air Handler
ODD
R
Y
B
W2
Y
W/BK
G/BK
BL
BR
G/Y
W/BL
R
Y
W2
*
FIGURE 12
TYPICAL THERMOSTAT: HEAT PUMP W / ELECTRIC HEAT
Humidistat
C
Heat Pump
Thermostat
Heat Pump
Outdoor Unit
D
B
G
Field Installed
Line Voltage
-
WIRING INFORMATION
Factory Standard
-
B
E
Y
R
C
R
W1
C
G
Air Handler
ODD
R
Y
B
W2
Y
W/BK
G/BK
BL
BR
G/Y
W/BL
R
Y
W2
*
FIGURE 13
TYPICAL THERMOSTAT: HEAT PUMP W / ELECTRIC HEAT USING A
HUMIDISTAT FOR DEHUMIDIFICATION
C
Y2
Heat Pump
Thermostat
Heat Pump
Outdoor Unit
D
B
G
Field Installed
Line Voltage
-
WIRING INFORMATION
Factory Standard
-
B
E
Y
R
C
R
W1
C
G
Air Handler
ODD
R
Y
B
W2
Y
W/BK
G/BK
BL
BR
G/Y
W/BL
R
Y
W2
FIGURE 14
TYPICAL THERMOSTAT: HEAT PUMP W / ELECTRIC HEAT USING A 2-
STG DEHUMIDIFYING THERMOSTAT
*
When using 13kW or higher, it is
recommitted to jump W1 and W2
together for maximum
outlet temperature rise.
*
When using 13kW or higher, it is
recommitted to jump W1 and W2
together for maximum
outlet temperature rise.
*
When using 13kW or higher, it is
recommitted to jump W1 and W2
together for maximum
outlet temperature rise.
*
When using 13kW or higher, it is
recommitted to jump W1 and W2
together for maximum
outlet temperature rise.
WIRE COLOR CODE:
BK - BLACK G - GREEN P - PINK W - WHITE
BR - BROWN GY - GRAY PR - PURPLE Y - YELLOW
GL - BLUE O - ORANGE R - RED
NOTE:
These low voltage application diagrams are generic. Your
indoor/outdoor units may not have all the characteristics shown or may
not wire exactly as shown. Refer to the diagrams and information sent
with your indoor/outdoor sections.
SINGLE STAGE
4.2B THERMOSTAT CONNECTIONS
(-)H1T continued on next page
15
Summary of Contents for FH2417PTSJSN