background image

1

fi-4110CU/M3091/M3092 S

ERIES

 C

ONSUMABLE

 R

EPLACEMENT

 

AND

 C

LEANING

 I

NSTRUCTIONS

fi-4110CU/M3091/M3092 S

ERIES

  C

ONSUMABLE

 R

EPLACEMENT

AND

 C

LEANING

 I

NSTRUCTIONS

CG00002-003401 Revision  A

Summary of Contents for fi-4110CU Series

Page 1: ...1 fi 4110CU M3091 M3092 SERIES CONSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS fi 4110CU M3091 M3092 SERIES CONSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS CG00002 003401 Revision A ...

Page 2: ...NSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS 2 KIT CONTENTS Cotton Swabs Qty 1 100 pack F1 Cleaner Isopropyl Alcohol Qty 1 Cleaning Paper Qty 1 10 pack Lint Free Cleaning Cloths Qty 2 20 pack Pad Assembly Qty 3 Guide Assembly Qty 1 ...

Page 3: ...with A4 Letter sized woodfree and wood based 17 lb paper NCR or Carbonless paper has chemical composition which damages the Pad and the Pick Roller Cleaning of the consumables will be required more frequently to avoid feed problems Consumable life will be reduced if NCR or Carbonless paper is scanned Pad Assembly Guide Assy CONSUMABLES PAGE COUNT Go to the Control Panel and Select Scanners and Cam...

Page 4: ...to Change Supplies is a rough estimate of when supplies should be changed with new ones This amount can vary depending on paper type frequency of use print on pages cleaning and other factors To order new consumables contact the Fujistsu Dealer in your area or call our Technical Assistance Center at the number in your documentation Clicking the Reset will set the count for each consumable to 0 Thi...

Page 5: ...DF button up Remove the Pad Assembly by pressing Down on the pick arm then pull out the pad assembly to remove it Attach the new Pad Assembly while pressing down on the pick arm so it is out of the way Be sure to seat the pad completely to avoid jamming of paper being fed Note After replacement of any consumable reset the counter for that consumable by following the Consumables Page Count Section ...

Page 6: ...r while holding up the cover open lever Push the Claw on the Guide Assembly inwards while lifting on the handle to remove the GuideAssembly from the scanner s feed path Remove Pick Roller Guide Handle Claw Note If the Guide Assembly is not fully seated paper jams and miss feeds are likely to occur Don t forget to reset the counter for the Pick Roller by right clicking on the ScanSnap Monitor in th...

Page 7: ...ntil you hear a click which indicates the ADF is fully closed The scanner should now be ready to feed documents See the Consumables Page Count Section of these instructions to reset paper counts This should be done when ever the consumables are changed out with new consumables REPLACING THE GUIDE ASSEMBLY CONT Push in Center to close ADF ADF Paper Chute ...

Page 8: ...ith toner that is not fused properly CLEANING MATERIALS Location Tools Frequency Cleaning Sheets Every 1 000 Sheets Cloth Isopropyl Alcohol Every 5 000 Sheets Plastic Feed Rollers Cloth Isopropyl Alcohol Every 5 000 Sheets Sheet Guides Cloth Isopropyl Alcohol Every 5 000 Sheets Eject Rollers Cloth Isopropyl Alcohol Every 5 000 Sheets Feed Rollers Cloth Isopropyl Alcohol Every 5 000 Sheets Glass Su...

Page 9: ...scribed later in this section Spray the Cleaning Paper lightly with F1 Cleaner and place the Cleaning paper against the right edge of the Hopper Guide Press the SCAN button on the front of the scanner to scan the cleaning paper Do Not Save These Images This operation is used only to pass the cleaning paper through the paper feed path Check the path to see if it needs further cleaning if you find d...

Page 10: ...d Assembly using a downward stroke in the direction shown to the right with the lint free cloth moistened lightly with F1 Cleaner 90 or higher IsopropylAlcohol CLEANING THE ADF WITH LINT FREE CLOTHS Note The glass surface inside the fi 4110EOX2 ADF becomes hot during scanner operation Before performing this cleaning turn off the scanner and disconnect the AC adapter from the power outlet wait at l...

Page 11: ...de together If you choose to clean the pick roller without removing it do so as shown below Clean the Pick Roller by wiping it lightly with a lint free cloth mostened with F1 Cleaner 90 or higher Isopropyl Alcohol Wipe lightly being careful not to break away parts of the rubber Clean the Plastic Feed Rollers Sheet Guides Eject Rollers Feed Rollers and Glass Guide Surfaces as required by spraying F...

Page 12: ...h a lint free cloth moistened with F1 Cleaner 90 or higher Isopropyl Alcohol Be careful not to damage the sponge HK rings at each end of the two plastic exit rollers Clean the Sheet Guide surface Glass Surface wiping them lightly with a lint free cloth moistened lightly with F1 Cleaner 90 or higher IsopropylAlcohol Pad Assembly Feed Rollers Eject Rollers Glass Plastic Rollers Pick Roller Sheet Gui...

Page 13: ...13 fi 4110CU M3091 M3092 SERIES CONSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS ...

Reviews: