Chapter 8 Operational Settings
174
Example 1:
Specified position: Left
Selected range = Disable, Start = 50 mm, End = 200 mm
Specified position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
Specified position: Right
Selected range = Disable, Start = 50 mm, End = 200 mm
Multifeed is detected only for the areas in light blue.
End
(Left/Middle/Right)
Displays the end point of the detection by
the length from the leading edge of the
document.
Configurable area: 0 to 510 mm (in
increments of 2 mm), Start < End
When both [Start] and [End] are set to "0", multifeed
detection is performed for the whole area regardless of
whether it is enabled or disabled.
To disable multifeed detection for the whole document,
select [Disable] and set the start position to "0" and the
end position to be equal to or longer than the
document length.
If the start position is set larger than the document
length: with [Disable], the whole range covering the
entire document length will be checked; with [Enable],
the multifeed detection will be disabled.
To detect multifeeds, the detection range must be at
least 8 mm in length.
Configure the settings so that the value of the end
position minus the start position is 6 mm or more.
You can also set the start and the end positions by one
of the following ways:
- Create a square or rectangle to indicate the
detection range by dragging your mouse pointer on
the displayed image in the dialog box.
- Drag the handle for the detection range to change
the start and end positions using the mouse pointer
on the displayed image in the dialog box.
Range
Description
35
35
35
60
60
50
200
Unit: mm
F
eed
ing d
irect
ion