Chapter 9 Operational Settings
171
*1: Displayed when using the fi-7260 or fi-7280.
*2: Displayed when the imprinter is installed.
Item
Description
Parameter/Value
Factory Default
Count
Check the counters to determine when to replace the
consumables and to perform cleaning.
Also use it to reset the counter when you have replaced the
consumables or performed cleaning.
Total Page Count(ADF) / Total Page Count(FB) (*1)/
After cleaning/Brake Roller/Pick Roller
0
Remaining Ink (when the imprinter is installed)
(*2)
Power saving
Specify the waiting time before entering power saving mode.
This setting can also be configured in the operator panel.
Range: 5 to 235 min. (in increments of 5)
15 min.
Power off after a certain period of time: Select to set the
scanner to turn the power off automatically if the scanner is left
on for a certain period of time without being used.
Specify the timeout period for the scanner to be automatically
turned off.
This setting can also be configured in the operator panel.
[Power off after a certain period of time] check box
Selected
1 Hour/2 Hours/4 Hours/8 Hours
(When the [Power off after a certain period of time]
check box is selected)
4 Hours
Offset Setting
Adjust the position to start the scan on the selected scanning
side(s).
Unit: Flat bed (*1) / ADF(front) / ADF(back)
Main/Sub: -2 to 2 mm
(in increments of 0.5)
Main/Sub: 0 mm
Vertical
magnification
Adjustment
Adjust the magnification level in feed direction for the selected
scanning method.
Unit: Flat bed (*1) / ADF
Range: -3.1 to 3.1% (in increments of 0.1)
0%