2.2: LED Descriptions
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.2-6
Maintenance and Trouble Clearing
FJTU-320-515-480
Table 2-7: LC1A-D1/-D1E/-D1E2 LED Descriptions
LED
Color
Meaning
FAIL/SVCE
Red
An internal failure, or the internal clock or building integrated timing supply
(BITS) output is down.
Blinking red
Unit MISMOUNT: the system is configured for a different mode, or the
mounted unit is not intended for use in the current configuration.
Green
Normal operation (in service).
Off
Standby or out of service.
LINE
Red
The incoming signal has degraded or failed. A service-affecting alarm (such as
a bipolar violation [BPV] within a DS1, or an LOS, LOF, or bit error rate [BER]
exists.
Yellow
One or more non–service-affecting path-level conditions exist. Possible
conditions include an AIS within the virtual tributary (VT) path, or an
unequipped code (UNEQ).
Off
Normal operation.
Table 2-8: LC1A-F6/-F6C1/-F6T1 LED Descriptions
LED
Color
Meaning
FAIL/SVCE
Red
An internal failure, or the internal clock or BITS output is down.
Blinking red
Unit MISMOUNT: the system is configured for a different mode, or the
mounted unit is not intended for use in the current configuration.
Green
Normal operation (in service).
Off
Standby or out of service.
Table 2-9: LS1A-D1 LED Descriptions
LED
Color
Meaning
FAIL/ON PTCT
Red
An internal failure
Green
Switched to protect
Off
Normal operation (in service)