5.8: Correcting a Mismounted Unit
Issue 9, May 1999
FNC and FNC Customer Use Only
Vol. ll, Page 480.5-27
Maintenance and Trouble Clearing
FJTU-320-515-480
5.8
Correcting a Mismounted Unit
5.8.1
Overview
A mismounted unit is indicated by a blinking red FAIL LED that denotes either of
the following troubles:
•
The slot is configured for a different type of unit.
•
The mounted unit is not used in this configuration.
No alarm is generated by a mismounted unit.
To correct a mismounted unit, use the appropriate procedure presented below:
FLEXR or TL1.
5.8.2
FLEXR Procedure
Step 1
Should the unit have been installed in another slot?
Step 2
Should a different unit have been installed in the slot?
If Yes:
If No:
Move the unit to the correct slot.
You have completed this procedure.
If Yes:
If No:
Replace the incorrect unit with a correct unit.
You have completed this procedure.
Go to Step 3 to retrieve
the current provisioning.