background image

Heat pump air/water

split, single service

Operation manual

intended for professionals

and end users.

To be saved

for future consultation

Fujitsu General (Euro) GmbH

Werftstrasse 20

40549 Düsseldorf - Germany

Subject to modifications without notice.

Non contractual document.

Document n° 1353-

3

~ 18/09/2009

F

Notice 1353

F

Pas de Nom (marque, produit)

F

dans prem_FUJITSU,
remplacer le marqueur de variable
- édition xxx par édition_FUJITSU

F

dans format de page, remplacer :
- N°_doc_xxx par N°_doc_FUJITSU

F

dans tronc commun,
remplacer en dernière page :
S10

,

S13

, and

S16

models

par
095, 112, 128, 140,155 and 160 models

FR

EN

NL

DE

IT

Summary of Contents for Heat pump

Page 1: ... professionals and end users To be saved for future consultation Fujitsu General Euro GmbH Werftstrasse 20 40549 Düsseldorf Germany Subject to modifications without notice Non contractual document Document n 1353 3 18 09 2009 F N F P F d re F d F d re S p 0 FR EN NL DE IT ...

Page 2: ...all view of the installation p 5 Operation of the installation p 6 User interface p 6 Appliance start up p 8 Quick start up p 8 Programming examples p 9 Structure of the End user control menu p 10 Parametering the setting p 11 General p 11 Setting parameters p 11 List of Consumer settings p 11 Information display p 15 Details p 15 Operation of the DHW system p 15 Selecting cooling mode p 15 Config...

Page 3: ...perating must be correctly ventilated in order to prevent any loss of oxygen if there is an escape of refrigerant gas F Consult your Installer before making any changes or modifications to the premises where the appliance is installed F Do not place any heat source under the remote control 1 1 3 Maintenance F Do not try to repair this appliance yourself F This appliance does not contain any compon...

Page 4: ...ption This second solution water control is the only one usable for Floor heating systems It is also very effective for thermostatically controlled radiators 1 2 4 Floor heating systems New floor heating systems require to be initially heated slowly to avoid any problems with cracking Check with your installer that this initial heating procedure has indeed been performed before using your heating ...

Page 5: ...Heat pumps are systems that can be connected to any form of low temperature heat distribution systems the heat captured by the heat pump can therefore be used in different ways Floor heating systems Radiators or warm fan coil heaters Domestic hot water DHW Instruction manual 1353 EN 5 Heat pump split single service or The outside unit The hydraulic unit Heating circuit Radiators or fan convectors ...

Page 6: ... 3 seconds Immediate DHW operation after use of the electrical back ups until the DHW comfort setting has been reached 2 Digital display Operating control Readout of the current temperature of the heating mode and of any faults View the settings 3 Exit ESC Quit the menu 4 Navigation and setting Selecting the menu Setting parameters Adjusting the ambient temperature setpoint Figure 2 1 2 3 4 5 6 7 ...

Page 7: ...ng mode If the installation is fitted with the cooling kit Cooling operating according to the heating programme Summer winter mode switchover is automatic 9 RESET button Hold down the RESET key for 3 seconds Reinitialising the parameters and cancelling error messages Do not use during normal operation 10 Selecting the heating mode Heating operating according to the heating programme Summer winter ...

Page 8: ...Data update and then State heat pump Select the AUTO heating mode Fig 5 Select the DHW mode Fig 5 if the installation is fitted with a DHW tank with electrical back up heating Set the current date and time Fig 6 8 Instruction manual 1353 EN Heat pump split single service Figure 3 Opening the door 1 2 3 Xxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxx Figure 4 Start ...

Page 9: ...te Press OK to confirm Press OK to confirm Turn the knob select line 1 Hours minutes The hour display flashes Press the key OK Turn the knob to set the time The minutes display flashes Press the key OK Turn the knob to set the minutes The setting are recorded Press a regime key to return to the standard display Turn the knob to make other settings or Keys Description Display example Room setpoint ...

Page 10: ...alues Mon Sun Mon Fri Sat Sun Monday Tuesday Sunday Period selection 1st phase On start 1st phase Off end Regime level Period Period Period 1 2 8 Reduced temp 35 C Temp frost free comfort 4 C temp réduite Comfort setting Reduced setting Frost free setpoint No Yes Heat pump Reset Off On Emergency regime HP return temp HP flow temp Compressor modul Time and date User interface CC1 time programme CC2...

Page 11: ...tically to the basic display Date and time 1 Hours minutes 00 00 23 59 1 2 Day Month 01 01 31 12 1 3 Year 1900 2099 1 User interface 20 Language English Français Italiano Nederlands Heating time programme circuit 1 500 Pre selection day week Mon Sun Mon Fri Sat Sun Monday Tuesday Mon Sun 501 1st phase On start 00 00 10 min 6 00 502 1st phase Off end 00 00 10 min 22 00 503 2nd phase On start 00 00 ...

Page 12: ...ion day week Mon Sun Mon Fri Sat Sun Monday Tuesday Mon Sun 561 1st phase On start 00 00 10 min 00 00 562 1st phase Off end 00 00 10 min 05 00 563 2nd phase On start 00 00 10 min 564 2nd phase Off end 00 00 10 min 565 3rd phase On start 00 00 10 min 566 3rd phase Off end 00 00 10 min 576 Standard values no yes no Yes OK The standard values memorised in the regulator replace and cancel the customis...

Page 13: ...circuit 1 If the installation is fitted with the cooling kit only with the cooling kit option 901 Operating mode Off Automatic Off 902 Comfort ambient temperature setpoint 17 40 C 0 5 C 24 C 907 Release 24h day Time programme HC Time programme 5 Refresh 24h day If the installation is fitted with a DHW tank set the parameter 907 to Time programme 5 Cooling in order to activate cooling only during t...

Page 14: ... 140 C Setpoint flow HP 0 140 C 8413 Compressor modulation 0 100 Diagnostics consumers 8700 External temperature 50 50 C 8701 Minimum external temperature Reset no yes 50 50 C 8702 Maximum external temperature Reset no yes 50 50 C 8721 Room temperature 0 50 C 8740 Room temperature 1 0 50 C 20 C Ambient temperature setting 1 4 35 C 20 8743 Flow temperature 1 0 140 C 50 Flow temperature setpoint 1 0...

Page 15: ...emperature 8410 Setpoint HP flow Heat pump flow temperature 8412 Setpoint HP flow Swimming pool temperature 8900 Swimming pool temperature setpoint 3 8 Details If the electrical power supply has been cut off while the heat pump is operating electrical power failure or unprogrammed pressing of the on off switch on the hydraulic unit the display will show error 370 when the appliance restarts Do not...

Page 16: ...ul not to damage the fins Check that there is nothing obstructing the passage of air 4 3 Checking the refrigeration circuit When the coolant fluid charge is in excess of 2kg 095 112 128 140 155 and 160 models it is compulsory to have an approved after sales service check the refrigeration circuit every year Consult your heating technician This appliance is marked with this symbol This means that e...

Reviews: