14
Instruction manual “1353-EN”
Heat pump, split, single service
Swimming pool (Only with swimming pool kit option)
2056
Generator heating setting
8... 35 °C
22 °C
Error
6711
Heat pump Reset
No, yes
No
Maintenance / special mode
7141
Emergency operation
Off, ON
Off
Off: The heat pump does not use the backup electrical heating system or the boiler connection when a fault
occurs (error 370)
ON: The heat pump uses the backup electrical system or the boiler connection when a fault occurs (error
370). In the "ON" position, the energy costs can be huge if the error is not eliminated.
Diagnostics heat generation
8410
Heat pump return temperature
0 … 140 °C
Setpoint (flow) HP
0 … 140 °C
8412
Heat pump flow temperature
0 … 140 °C
Setpoint (flow) HP
0 … 140 °C
8413
Compressor modulation
0 … 100%
Diagnostics consumers
8700
External temperature
-50 .. 50 °C
8701
Minimum external temperature
Reset ? (no, yes)
-50 .. 50 °C
8702
Maximum external temperature
Reset ? (no, yes)
-50 .. 50 °C
8721
Room temperature
0 .. 50 °C
8740
Room temperature 1
0 … 50 °C
20 °C
Ambient temperature setting 1
4 … 35 °C
20
8743
Flow temperature 1
0 … 140 °C
50
Flow temperature setpoint 1
0 … 140 °C
50
8756
Cooling flow temperature 1
0 … 140 °C
0
Cooling flow temperature setpoint 1
0 … 140 °C
0
8770
Room temperature 2
0 … 50 °C
20
Ambient temperature setpoint 2
4 … 35 °C
20
8773
Flow temperature 2
0 … 140 °C
50
Flow temperature setpoint 2
0 … 140 °C
50
8830
DHW (domestic hot water) temperature
0 … 140 °C
DHW temperature setpoint
5 … 80 °C
50
8900
Swimming pool temperature
0 … 140 °C
Swimming pool temperature setpoint
0 … 80 °C
24
Line
Function
Setting range or
display
Setting
increment
B a s i c
setting