Important
-
Be
sure
to
save
the
logical
domain
configuration
information
before
changing
the
CPU
operational
mode.
The
logical
domain
configuration
information
for
Oracle
VM
Server
for
SPARC
includes
CPU
operation
information
used
by
the
logical
domain.
If
the
configuration
information
of
a
logical
domain
operating
by
using
SPARC64
X+
functions
is
applied
to
a
physical
partition
operating
by
using
SPARC64
X
functions,
inconsistency
in
the
configuration
information
is
detected.
In
this
case,
the
XSCF
switches
the
logical
domain
configuration
information
to
factory-default,
and
then
starts
the
physical
partition.
Since
the
logical
domain
configuration
information
that
has
been
saved
beforehand
is
required
for
reconfiguration
of
the
logical
domain,
be
sure
to
save
the
data
before
changing
the
CPU
operational
mode
with
the
setpparmode
command.
For
details
on
saving
and
restoring
logical
domain
configuration
information,
see
"1.7.3
How
to
save/restore
the
logical
domain
configuration
information
and
the
OpenBoot
PROM
environment
variable"
in
the
PCI
Expansion
Unit
for
Fujitsu
M10/SPARC
M10
Systems
Service
Manual
.
Table
8-3
Relationship
between
the
physical
partition
configuration,
setting
value
of
the
CPU
operational
mode,
and
CPU
operation
Physical
partition
configuration
Setting
value
of
the
CPU
operational
mode
CPU
operation
SPARC64
X+
auto
Operation
by
using
SPARC64
X+
functions
SPARC64
X+
compatible
Operation
compatible
with
the
SPARC64
X
SPARC64
X+
and
X
mixed
auto
or
compatible
As
to
the
SPARC64
X+,
operation
compatible
with
the
SPARC64
X
SPARC64
X
auto
or
compatible
Operation
by
using
SPARC64
X
functions
Note
-
When
adding
a
SPARC64
X
processor
to
a
PPAR,
you
must
shut
down
the
PPAR
before
adding
the
PSB
to
the
PPAR.
in
the
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide
.
■
CPU
configuration
and
CPU
operational
mode
of
the
physical
partition
shows
the
relationship
between
the
physical
partition
configuration,
setting
value
of
the
CPU
operational
mode,
and
CPU
operation.
8.3
Confirming
the
Removal
Pattern
of
a
Building
Block
Configuration
This
section
describes
the
removal
patterns
of
the
SPARC
M10-4S
and
crossbar
boxes
and
the
points
of
concern
during
removal.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
・
July
2015
232
Summary of Contents for M10 Series
Page 1: ...Fujitsu M10 SPARC M10 Systems Installation Guide Manual Code C120 E678 12EN July 2015 ...
Page 10: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 x ...
Page 156: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 142 ...
Page 176: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 162 ...
Page 208: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 194 ...
Page 240: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 226 ...
Page 252: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 238 ...
Page 290: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 276 ...
Page 310: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 296 ...
Page 336: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 322 ...
Page 368: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 354 ...
Page 374: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 360 ...