Note
-
If
the
serial
number
of
the
chassis
of
the
master
XSCF
is
not
being
used
as
the
system
serial
number,
execute
the
switchscf
command
to
switch
the
master
XSCF.
XSCF>
poweroff
-y
-a
PPAR-IDs
to
power
off:00,01,02
03
Continue?
[y|n]:y
00:Powering
off
01:Powering
off
02:Powering
off
03:Powering
off
XSCF>
deleteboard
-c
unassign
00-0
01-0
02-0
03-0
PSB#00-0
will
be
unassigned
from
PPAR
immediately.
Continue?[y|n]
:
y
PSB#01-0
will
be
unassigned
from
PPAR
immediately.
Continue?[y|n]
:
y
PSB#02-0
will
be
unassigned
from
PPAR
immediately.
Continue?[y|n]
:
y
PSB#03-0
will
be
unassigned
from
PPAR
immediately.
Continue?[y|n]
:
y
XSCF>
showresult
0
■
For
the
initialization
of
the
chassis
of
the
master
XSCF,
perform
that
work
at
the
end.
Execute
the
restoredefaults
-c
factory
command
to
return
to
the
factory
defaults,
including
the
CPU
Activation
key
information.
Perform
this
work
with
a
serial
connection
to
the
master
XSCF.
For
XCP
2041
or
later,
execute
the
restoredefaults
-c
factory
-r
activation
command.
The
key
must
be
reinstalled
at
initial
setup
of
the
XSCF
after
installation.
1.
Log
in
to
the
master
XSCF.
2.
Execute
the
showhardconf
command,
and
confirm
the
chassis
serial
number
of
the
system
board
(PSB)
targeted
for
release.
For
details,
see
3.
Execute
the
poweroff
command
to
stop
all
the
physical
partitions.
4.
Execute
the
deleteboard
command
from
the
master
XSCF
to
release
a
system
board
(PSB)
from
the
physical
partition
configuration.
The
following
example
releases
system
boards
00-0,
01-0,
02-0,
and
03-0
from
the
physical
partition.
5.
Execute
the
showresult
command,
and
confirm
the
end
status
of
the
previously
executed
deleteboard
command.
In
the
following
example,
0
is
returned
as
the
end
status,
so
the
execution
of
the
deleteboard
command
has
completed
correctly.
6.
Execute
the
showboards
command
to
check
the
system
board
(PSB)
status.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
・
July
2015
272
Summary of Contents for M10 Series
Page 1: ...Fujitsu M10 SPARC M10 Systems Installation Guide Manual Code C120 E678 12EN July 2015 ...
Page 10: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 x ...
Page 156: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 142 ...
Page 176: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 162 ...
Page 208: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 194 ...
Page 240: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 226 ...
Page 252: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 238 ...
Page 290: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 276 ...
Page 310: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 296 ...
Page 336: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 322 ...
Page 368: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 354 ...
Page 374: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 360 ...