XSCF>
showboards
-a
PSB
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
----
------------
-----------
----
----
----
-------
--------
00-0
SP
Available
n
n
n
Passed
Normal
01-0
SP
Available
n
n
n
Passed
Normal
02-0
SP
Available
n
n
n
Passed
Normal
03-0
SP
Available
n
n
n
Passed
Normal
XSCF>
initbb
-b
bb_id
XSCF>
initbb
-b
3
You
are
about
to
initialize
BB/XB-Box.
NOTE
the
following.
1.
BB/XB-Box
is
excluded
from
the
system
and
halted.
2.
PPAR-ID
of
the
same
value
as
BB-ID
becomes
invalid.
Continue?
[y|n]
:
y
Note
-
After
the
execution
of
the
initbb
command,
the
target
chassis
is
released
from
the
system
and
enters
the
stopped
state.
Do
not
disconnect
the
power
cords
or
various
cables
until
the
XSCF
STANDBY
LED
on
the
panel
and
the
rear
READY
LED
of
the
target
chassis
are
off.
Note
-
For
the
initialization
of
the
chassis
of
the
master
XSCF,
perform
that
work
at
the
end.
Execute
the
restoredefaults
-c
factory
command
to
return
to
the
factory
defaults,
including
the
CPU
Activation
key
information.
Perform
this
work
with
a
serial
connection
to
the
master
XSCF.
For
XCP
2041
or
later,
execute
the
restoredefaults
-c
factory
-r
activation
command.
The
key
must
be
reinstalled
at
initial
setup
of
the
XSCF
after
installation.
7.
Execute
the
initbb
command
from
the
master
XSCF
to
release
the
target
SPARC
M10-4S
from
the
system
and
initialize
it.
In
bb_id,
specify
the
ID
(BB-ID)
identifying
the
chassis.
The
following
example
releases
BB#03
from
the
system
and
initializes
it.
8.
Remove
the
power
cords
from
the
power
supply
units
of
the
target
SPARC
M10-4S.
9.
Remove
the
XSCF
BB
control
cables
from
the
target
SPARC
M10-4S.
10.
Remove
the
crossbar
cables
from
the
target
SPARC
M10-4S.
11.
You
are
performing
removal
to
the
1BB
configuration.
So,
remove
the
XSCF
DUAL
control
cable.
12.
Remove
the
target
SPARC
M10-4S
from
the
rack.
Remove
the
SPARC
M10-4S
from
the
rack
by
reversing
the
mounting
procedure.
For
the
procedure
for
mounting
in
the
rack,
see
"
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
・
July
2015
292
Summary of Contents for M10 Series
Page 1: ...Fujitsu M10 SPARC M10 Systems Installation Guide Manual Code C120 E678 12EN July 2015 ...
Page 10: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 x ...
Page 156: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 142 ...
Page 176: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 162 ...
Page 208: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 194 ...
Page 240: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 226 ...
Page 252: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 238 ...
Page 290: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 276 ...
Page 310: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 296 ...
Page 336: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 322 ...
Page 368: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 354 ...
Page 374: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 360 ...