Table
A-1
List
of
problem
case
examples
(continued)
Case
Possible
cause
Corrective
action
After
the
input
power
is
turned
on,
the
MASTER
LEDs
on
all
chassis
are
lit.
BB-IDs
have
not
been
set.
Initialize
each
chassis
to
the
factory
default
settings,
and
change
the
BB-IDs
to
the
correct
settings.
See
The
XCP
version
check
displays
only
BB#00.
BB-IDs
have
not
been
set.
Initialize
each
chassis
to
the
factory
default
settings,
and
change
the
BB-IDs
to
the
correct
settings.
See
The
XCP
version
check
displays
only
BB#00
and
BB#01
even
though
the
configuration
has
at
least
three
BBs.
The
BB-IDs
of
BB#00
and
BB#01
are
reversed.
Initialize
BB#00
and
BB#01
to
the
factory
default
settings,
and
change
the
BB-IDs
to
the
correct
settings.
See
The
XCP
version
check
does
not
display
BB#03
even
though
the
configuration
has
four
BBs.
BB#03
has
the
wrong
BB-ID
setting. Change
the
BB-ID
to
the
correct
setting.
See
The
component
status
check
(by
the
showhardconf
command)
of
a
building
block
configuration
displays
only
BB#00.
The
XSCF
cables
between
chassis
are
incorrectly
connected.
Check
messages
by
using
the
showlogs
command.
See
"Failed"
appears
in
the
results
of
a
diagnosis
test
performed
on
a
building
block
configuration.
The
crossbar
cables
between
chassis
are
incorrectly
connected.
Check
messages
by
using
the
showlogs
command.
See
A.2
Understanding
Commands
for
Troubleshooting
This
section
describes
the
XSCF
shell
commands
used
to
check
detailed
error
information
and
the
system
status.
A.2.1
Checking
the
component
status
Use
the
showhardconf
command
to
check
the
status
of
each
field
replaceable
unit
(FRU).
The
displayed
information
is
as
follows:
■
Current
configuration
and
status
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
・
July
2015
298
Summary of Contents for M10 Series
Page 1: ...Fujitsu M10 SPARC M10 Systems Installation Guide Manual Code C120 E678 12EN July 2015 ...
Page 10: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 x ...
Page 156: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 142 ...
Page 176: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 162 ...
Page 208: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 194 ...
Page 240: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 226 ...
Page 252: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 238 ...
Page 290: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 276 ...
Page 310: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 296 ...
Page 336: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 322 ...
Page 368: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 354 ...
Page 374: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 360 ...