Table
2-13
Electrical
specifications
(Expansion
rack:
Single-phase
power
feed
model)
(*1)
(continued)
Item
Specification
1
expansion
rack
2
expansion
racks
Input
voltage
200
to
240
VAC
200
to
240
VAC
Leakage
current
(*3)
(*4)
3.5
mA
3.5
mA
*1
The
specifications
apply
to
a
single
rack.
*2
For
the
M10-4S
mounted
in
an
expansion
rack.
If
the
mounted
device
is
not
the
M10-4S,
the
configuration
may
be
different
depending
on
the
power
connection
configuration
of
the
device.
*3
The
value
is
the
tolerance
per
power
cord.
The
actual
current
value
depends
on
the
rating
of
the
device
mounted
in
the
expansion
rack.
*4
The
value
is
for
an
expansion
rack
without
the
M10-4S
and
other
devices
mounted.
(Only
crossbar
boxes
are
mounted.)
Only
the
two
power
cords
use
power.
If
the
M10-4S
or
other
devices
are
mounted,
the
current
values
and
the
number
of
power
cords
that
consume
power
are
different.
*5
The
current
that
flows
through
each
power
cord
in
a
redundant
configuration
is
half
the
value
listed
in
Table
2-14
Electrical
specifications
(Expansion
rack:
Three-phase
delta
power
feed
model)
(*1)
Item
Specification
1
expansion
rack
2
expansion
racks
Input
voltage
200
to
240
VAC
200
to
240
VAC
Number
of
power
cords
6
6
Power
cord
length
4.0
m
(13.1
ft.)
4.0
m
(13.1
ft.)
Redundancy
(*2)
1+1
redundant
configuration
1+1
redundant
configuration
Frequency
50
Hz/60
Hz
50
Hz/60
Hz
Rated
current
(*3)
Maximum
of
35
A
Maximum
of
35
A
Rated
current
(*4)
(*5)
4.0
A
5.2
A
Maximum
power
consumption
(*4) 1,354
W
1,754
W
Apparent
power
(*4)
1,382
VA
1,790
VA
Rush
current
(*3)
(*4)
80
A
peak
or
less
80
A
peak
or
less
Leakage
current
(*3)
(*4)
3.5
mA
3.5
mA
*1
The
specifications
apply
to
a
single
rack.
*2
For
the
M10-4S
mounted
in
an
expansion
rack.
If
the
mounted
device
is
not
the
M10-4S,
the
configuration
may
be
different
depending
on
the
power
connection
configuration
of
the
device.
*3
The
value
is
the
tolerance
per
power
cord.
The
actual
current
value
depends
on
the
rating
of
the
device
mounted
in
the
expansion
rack.
*4
The
value
is
for
an
expansion
rack
without
the
M10-4S
and
other
devices
mounted.
(Only
crossbar
boxes
are
mounted.)
Only
the
two
power
cords
use
power.
If
the
M10-4S
or
other
devices
are
mounted,
the
current
values
and
the
number
of
power
cords
that
consume
power
are
different.
*5
The
current
that
flows
through
each
power
cord
in
a
redundant
configuration
is
half
the
value
listed
in
Table
2-15
Electrical
specifications
(Expansion
rack:
Three-phase
star
power
feed
model)
(*1)
Item
Specification
1
expansion
rack
2
expansion
racks
Input
voltage
380
to
415
VAC
380
to
415
VAC
Number
of
power
cords
6
6
Power
cord
length
4.0
m
(13.1
ft.)
4.0
m
(13.1
ft.)
Chapter
2
Planning
and
Preparing
for
System
Installation
57
Summary of Contents for M10 Series
Page 1: ...Fujitsu M10 SPARC M10 Systems Installation Guide Manual Code C120 E678 12EN July 2015 ...
Page 10: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 x ...
Page 156: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 142 ...
Page 176: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 162 ...
Page 208: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 194 ...
Page 240: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 226 ...
Page 252: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 238 ...
Page 290: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 276 ...
Page 310: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 296 ...
Page 336: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 322 ...
Page 368: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 354 ...
Page 374: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 360 ...