Table
3-15
Problems
resolved
in
XCP
2090
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
130305-009
x
x
x
Suppose
that
129
or
more
IP
addresses
of
the
trap
hosts
are
registered
by
the
setsnmp
addtraphost
or
setsnmp
addv3traphost
command.
Then,
executing
the
showsnmp(8)
command
displays
each
of
the
SNMPv1,
SNMPv2,
SNMPv2-inform,
and
SNMPv3
trap
hosts,
up
to
a
maximum
of
128
entries.
Similarly,
suppose
that
129
or
more
entries
are
registered
by
the
setsnmpusm
create,
setsnmpvacm
creategroup,
setsnmpvacm
createview,
or
setsnmpvacm
createaccess
command.
Then,
executing
the
showsnmpusm
or
showsnmpvacm
command
displays
no
more
than
128
entries
for
a
user,
view,
group,
and
access.
There
is
no
effective
workaround.
When
129
or
more
data
entries
are
registered
by
the
setsnmp(8),
setsnmpusm(8),
or
setsnmpvacm(8)
command
without
an
abnormal
end,
the
data
entries
have
been
registered
successfully.
RTIF2-
131023-003
x
x
x
OID
of
scfDomainInfoGroup
is
duplicated
and
defined
in
the
MIB
definition
file
for
XSCF
expansion.
Therefore,
any
attempt
to
install
the
MIB
definition
file
for
XSCF
expansion
in
the
server
management
software
(e.g.,
JP1/Integrated
Management
manufactured
by
Hitachi)
may
fail.
Delete
the
line
of
text
of
the
duplicated
OID
from
the
MIB
definition
file
for
XSCF
expansion.
Then,
install
the
MIB
definition
file
for
XSCF
expansion
again.
The
line
of
text
to
be
deleted
is
that
in
which
scfDomainInfoGroup
containing
"::=
{
scfMIBObjectGroups
14
}"
is
defined.
[Example]
For
the
MIB
definition
file
for
XSCF
expansion
(XSCF-SP-MIB_2050.mib),
delete
the
following
lines
3558
to
3566.
--------------
3558:
scfDomainInfoGroup
OBJECT-
GROUP
3559:
OBJECTS
{
3560:
scfDomainNumber,
scfPPARId,
scfDomainName,
3561:
scfDomainStatus
3562:
}
3563:
STATUS
current
3564:
DESCRIPTION
3565:
"A
collection
of
objects
providing
PPAR
information."
3566:
::=
{
scfMIBObjectGroups
14
}
--------------
RTIF2-
131107-001
x
If
the
XSCF
BB
control
cable
is
faulty
or
loose
or
if
an
XSCF
failure
occurs,
it
may
take
several
hours
to
disconnect
or
reset
the
power
supply
of
the
physical
partition
(PPAR)
consisting
of
multiple
SPARC
M10-4S
units.
There
is
no
effective
workaround.
Chapter
3
Information
on
Software
117
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...