Table
3-15
Problems
resolved
in
XCP
2090
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131112-011
x
x
x
If
the
physical
partition
(PPAR)
is
powered
on
and
then
the
ioxadm(8)
command
is
executed
before
the
power-on
processing
is
complete,
the
error
log
"SCF
process
down
detected"
is
registered,
and
the
ioxadm(8)
command
may
fail.
Do
not
execute
the
ioxadm(8)
command
until
the
PPAR
power-on
processing
is
complete.
You
can
check
the
progress
of
the
PPAR
power-on
processing
by
executing
the
showpparstatus(8)
command.
If
the
"Running"
message
appears
as
a
result
of
executing
the
showpparstatus(8)
command,
it
indicates
that
the
PPAR
power-on
processing
has
been
completed.
Once
the
PPAR
power-on
processing
has
been
completed,
execute
the
ioxadm(8)
command
again.
RTIF2-
131112-012
x
x
x
Suppose
that
the
error
log
"FAN
speed
too
high"
is
registered
because
of
an
excessive
fan
rotation
count.
Subsequently,
if
an
event
that
changes
the
fan
rotation
speed
occurs,
the
fan
rotation
speed
may
not
be
switched
to
the
correct
value
and
instead
may
be
switched
to
level
5
(full
speed).
If
an
event
that
changes
the
fan
rotation
speed
occurs,
the
following
event
logs
are
registered.
However,
the
displayed
fan
rotation
speed
will
not
be
correct.
The
actual
fan
rotation
speed
level
is
5,
which
is
full
speed.
-
Low
temperature
was
detected
at
air
inlet.
FANs
are
changed
to
speed
(level-1)
mode
-
Low
temperature
was
detected
at
air
inlet.
FANs
are
changed
to
speed
(level-2)
mode
-
Middle
temperature
was
detected
at
air
inlet.
FANs
are
changed
to
speed
(level-3)
mode
-
High
temperature
was
detected
at
air
inlet.
FANs
are
changed
to
speed
(level-4)
mode
-
Air
outlet
temperature
recovered
from
warning
state
There
is
no
effective
workaround.
[How
to
restore]
Replace
the
fan
of
the
detected
excessive
rotation
speed
error.
Chapter
3
Information
on
Software
119
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...