Table
3-15
Problems
resolved
in
XCP
2090
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131112-014
x
x
x
If
the
following
server
is
being
used
and
REMCS
registration
or
REMCS
environment
setting
is
performed,
a
communication
timeout
with
the
server
is
detected,
causing
processing
to
fail.
-
Windows
ExchangeServer
-
E-PORT
-
qmail
After
changing
the
server
to
be
used
to
sendmail
or
postfix,
perform
REMCS
registration
or
REMCS
environment
setting.
If
it
is
difficult
to
change
the
server,
update
its
firmware
to
XCP
2090
or
later.
RTIF2-
131112-015
x
If
the
initbb(8)
or
replacefru(8)
command
is
executed,
an
event
log
stating
"Change
Master
Failed"
may
be
registered.
There
is
no
effective
workaround.
Ignore
the
event
log.
RTIF2-
131126-001
x
x
x
Suppose
that
a
system
satisfying
one
of
the
conditions
described
in
[Conditions]
sets
the
power
supply
interlocking
function.
If
Oracle
Solaris
is
running
and
one
of
the
events
mentioned
in
[Event]
occurs,
an
external
I/O
device
may
be
erroneously
powered
off.
[Conditions]
-
A
single
SPARC
M10
system
is
registered
in
the
power
supply
interlocking
group.
-
Multiple
SPARC
M10
systems
are
registered
in
the
power
supply
interlocking
group,
and
the
physical
partitions
other
than
those
of
the
SPARC
M10
system
that
resets
the
XSCF
are
powered
off.
[Event]
-
Firmware
update
was
executed
from
the
flashupdate(8)
command
and
XSCF
Web,
and
the
XSCF
was
reset.
-
The
XSCF
was
reactivated
from
the
rebootxscf(8)
command
and
XSCF
Web,
and
the
XSCF
was
reset.
-
The
XSCF
was
reset
because
of
a
failure.
Apply
either
of
the
following
countermeasures:
-
Before
firmware
update
or
XSCF
reactivation,
execute
the
setremotepwrmgmt
-c
disable
command
to
disable
the
power
supply
interlocking
function.
Subsequently,
update
the
firmware
or
reactivate
the
XSCF.
After
the
XSCF
has
been
activated,
execute
the
setremotepwrmgmt
-c
enable
command
to
enable
the
power
supply
interlocking
function.
-
Disable
the
power
supply
interlocking
function
with
the
setremotepwrmgmt
-c
disable
command
and
then
manually
power
on
the
external
I/O
device.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
120
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...