Table
3-17
Problems
resolved
in
XCP
2070
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
130802-002
x
x
x
When
Oracle
Solaris
is
operating,
if
you
change
the
SNMP
setting
with
the
setsnmp(8)
command,
the
following
phenomena
may
occur.
1.
A
part
of
the
data
such
as
the
XCP
version
number
is
not
output
as
a
result
of
the
prtpicl
-v
and
prtdiag
-v
commands.
2.
For
/var/adm/messages
of
Oracle
Solaris,
the
following
warning
message
is
output.
PICL
snmpplugin:
cannot
fetch
object
value
There
is
no
effective
workaround.
-
If
1.
occurs:
Perform
recovery
by
using
the
following
procedure.
1)
End
the
prtdiag
command
with
[Ctrl]
+
[C].
2)
Wait
for
about
30
minutes,
and
let
an
SNMP
timeout
occur
in
the
XSCF.
3)
On
the
logical
domain,
execute
the
svcadm
command
to
restart
the
picl
service.
-
If
2.
occurs:
The
system
can
be
operated
continuously
because
this
is
a
temporary
warning
message.
RTIF2-
130826-001
x
If
you
log
in
to
the
XSCF
Web
from
the
master
XSCF
when
the
standby
XSCF
is
in
either
the
maintenance
or
input
power
off
state,
a
dialog
starting
with
"Cannot
communicate
with
BB#xxx:
..."
that
indicates
a
non-breaking
communication
error
is
output.
There
is
no
effective
workaround.
The
message
in
the
dialog
indicates
a
display
defect,
so
you
can
operate
the
system
as
is.
Ignore
the
dialog
related
to
this
communication
error.
RTIF2-
130902-001
x
If
the
firmware
is
updated
while
a
logical
domain
is
operating
in
a
system
consisting
of
multiple
SPARC
M10-4S
units,
the
master
XSCF
may
not
switch
to
a
standby
XSCF,
causing
the
firmware
update
to
fail.
There
is
no
effective
workaround.
Recover
the
system
by
following
the
procedure
described
below.
1.
Log
in
to
either
standby
XSCF,
and
then
execute
the
following
command.
XSCF>
rebootxscf
-s
2.
After
10
seconds,
log
in
to
the
other
standby
XSCF,
and
then
execute
the
following
command.
XSCF>
rebootxscf
-a
3.
Wait
for
20
minutes,
log
in
to
the
master
XSCF,
and
then
execute
the
flashupdate(8)
command
again.
RTIF2-
130903-002
x
In
a
system
consisting
of
multiple
SPARC
M10-4S
units,
it
may
take
longer
than
usual
from
the
time
a
physical
partition
(PPAR)
is
turned
on
until
the
Power-On
Self
test
(POST)
starts.
For
example,
for
a
2BB
configuration,
POST
usually
starts
after
about
10
minutes,
but
it
may
take
20
minutes
or
longer.
There
is
no
effective
workaround.
If
this
defect
occurs,
execute
the
rebootxscf
-a
command
to
reset
all
the
XSCFs
and
restore
the
system.
Chapter
3
Information
on
Software
131
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...