performed,
not
only
the
DR
processing
will
terminate
abnormally,
Oracle
Solaris
on
a
running
physical
partition
may
hang,
hardware
failure
may
occur,
physical
partitions
may
stop
abnormally
and
replacement
of
parts
may
become
necessary.
■
If
even
one
logical
domain
in
the
OpenBoot
PROM
state
is
situated
in
the
physical
partition,
dynamically
reconfiguring
the
physical
partition
causes
it
to
end
with
an
error.
Execute
dynamic
reconfiguration
of
the
physical
partition
after
changing
the
logical
domain
to
any
of
the
following
states:
state
where
Oracle
Solaris
is
running,
bound
state,
or
inactive
state.
■
Do
not
specify
either
"unbind=resource"
or
"unbind=shutdown"
at
the
"-m"
option
of
the
deleteboard(8)
command
when
executing
dynamic
reconfiguration
of
physical
partitions
where
the
version
of
Oracle
VM
Server
for
SPARC
is
earlier
than
3.2,
as
there
is
a
chance
of
the
logical
domain
to
hang
or
the
deleteboard(8)
command
to
fail.
Due
to
this
problem,
memory
module
(DIMM)
of
different
capacities
cannot
be
mounted
on
a
chassis,
which
is
the
target
of
the
dynamic
reconfiguration
of
physical
partitions.
Make
sure
that
the
mounted
memory
modules
(DIMMs)
on
chassis
whose
physical
partition
is
the
target
of
dynamic
reconfiguration,
are
all
of
the
same
capacity.
Meanwhile,
there
is
no
problem
if
the
number
of
DIMMs
differs
from
chassis
to
chassis.
■
Do
not
apply
patches
150400-01
to
150400-06
on
Oracle
Solaris
10.
In
such
a
case,
dynamic
reconfiguration
of
physical
partitions
may
cause
system
panic
(CR
17510986).
Notes
on
mixing
SPARC64
X+
processors
with
SPARC64
X
processors
To
mix
SPARC64
X+
processors
with
SPARC64
X
processors,
configure
each
type
in
a
unit
of
the
SPARC
M10
system
chassis,
which
is
the
system
board
configuration
unit.
SPARC64
X+
processors
cannot
be
mixed
with
SPARC64
X
processors
and
mounted
together
inside
each
chassis
in
the
SPARC
M10
system.
In
the
SPARC
M10-4/M10-4S,
there
are
systems
configured
with
the
CPU
memory
unit
lower
(CMUL)
and
CPU
memory
unit
upper
(CMUU).
These
units
must
have
the
same
processor.
Notes
and
restrictions
on
the
SR-IOV
functions
Notes
■
If
the
maintenance
of
PCI
Express
(PCIe)
cards
that
use
the
SR-IOV
function
is
performed
either
with
dynamic
reconfiguration
(DR)
of
physical
partitions
or
with
PCI
hot
plugging
(PHP),
execute
the
following
procedure
beforehand:
1.
Remove
all
virtual
functions
(VF)
from
the
I/O
domains
by
executing
the
"ldm
remove-io"
command.
Chapter
2
XCP
2240-Related
Information
13
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...