Table
2-4
Work
to
be
performed
after
you
add,
remove,
or
replace
a
PCI
expansion
unit
for
a
PCI
slot
of
SPARC
M10
chassis
for
which
the
direct
I/O
function
is
enabled
(continued)
Maintenance
environment
Domain
configuration
Reconstructing
Oracle
VM
Server
for
SPARC
config
Setting
OpenBoot
PROM
environment
variables
again
When
a
normal
PCI
expansion
unit(*1)
is
replaced
by
stopping
the
PPAR
factory-default
Guest
domain
exists.
Unnecessary
Unnecessary
Unnecessary
Unnecessary
*1
Includes
cases
in
which
a
link
card,
link
cable,
management
cable,
or
link
board
is
replaced.
Notes
on
dual
power
feed
setting
The
power
supply
unit
of
the
SPARC
M10
system
is
redundantly
configured.
Enabling
or
disabling
the
dual
power
feed
function
with
the
setdualpowerfeed(8)
command
does
not
affect
the
behavior
of
a
redundantly
configured
system.
Therefore,
when
the
display
results
of
the
showdualpowerfeed(8)
and
showhardconf
(8)
commands,
which
are
dependent
on
the
setting
of
the
setdualpowerfeed(8)
command,
also
fall
under
any
of
the
following
conditions,
the
behavior
of
the
redundantly
configured
system
is
not
affected.
■
The
showhardconf(8)
command
displays
"Power_Supply_System:
Dual;"
when
the
showdualpowerfeed(8)
command
displays
"Dual
power
feed
is
enabled."
■
The
showhardconf(8)
command
displays
"Power_Supply_System:
Single;"
when
the
showdualpowerfeed(8)
command
displays
"Dual
power
feed
is
disabled."
The
system
administrator
can
use
this
setting
function
as
a
memo
for
determining
whether
the
power
supply
unit
has
a
dual
power
feed
configuration.
Notes
on
Active
Directory
■
If
Active
Directory
is
enabled
and
you
try
login
via
telnet,
inquiry
to
the
second
and
subsequent
alternative
servers
may
time
out,
causing
the
login
to
fail.
■
If
the
value
set
by
the
timeout
operand
of
the
setad(8)
command
is
small,
and
you
log
in
to
the
XSCF,
the
user
privilege
may
not
be
assigned
to
you.
In
this
case,
increase
the
timeout
setting
value
and
try
again.
Notes
on
LDAP
over
SSL
If
the
value
set
by
the
timeout
operand
of
the
setldapssl(8)
command
is
small,
and
you
log
in
to
the
XSCF,
the
user
privilege
may
not
be
assigned
to
you.
In
this
case,
increase
the
timeout
setting
value
and
try
again.
Chapter
2
XCP
2240-Related
Information
23
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...