XSCF>
setpparparam
-p
xx
-s
bootscript
"setenv
auto-boot?
false"
XSCF>
function
of
the
control
domain.
13.
Similarly,
execute
the
ldm
add-spconfig
command
for
the
guest
domain
after
adjusting
the
time
of
Oracle
Solaris.
Notes
on
Timezones
The
time
zones
(regions/place
names)
supported
by
the
XSCF
can
be
changed
to
support
the
latest
time
zone
information.
For
any
previously
set
time
zone
that
the
system
cannot
use
anymore,
the
XSCF
switches
from
this
unusable
time
zone
to
Coordinated
Universal
Time
(UTC)
and
operates
in
UTC.
When
the
set
time
zone
operates
in
UTC,
execute
the
settimezone
-c
settz
-a
command,
and
check
the
settable
time
zones.
If
the
time
zone
list
does
not
have
a
set
time
zone,
set
a
time
zone
again.
Notes
on
power
supply
interlock
function
(RCIL)
■
Do
not
register
the
same
node
with
multiple
power
supply
interlocking
groups.
If
power
supply
interlocking
is
performed
by
registering
a
single
node
with
multiple
power
supply
interlocking
groups,
the
operation
may
not
be
as
intended.
With
the
setremotepwrmgmt(8)
command,
you
cannot
confirm
whether
a
single
node
is
registered
with
multiple
power
supply
interlocking
groups.
When
creating
or
modifying
a
power
supply
interlocking
group
management
information
file,
take
care
not
to
cause
overlaps.
■
Do
not
register
an
I/O
node
with
multiple
power
control
groups.
If
the
same
I/O
node
is
set
with
multiple
power
supply
interlocking
groups,
and
both
of
the
conditions
below
are
met,
the
I/O
node
is
turned
on
and
off
alternately.
-
setremotepwrmgmt
-c
enable
is
executed,
and
the
power
supply
interlocking
function
is
enabled.
-
There
is
a
power
control
group
in
which
one
or
more
host
nodes
are
on,
and
there
is
a
power
control
group
in
which
all
the
host
nodes
are
off.
If
you
accidentally
register
an
I/O
node
with
multiple
power
control
groups,
use
setremotepwrmgmt
-c
disable
to
disable
power
supply
interlocking
first
and
then
use
clearremotepwrmgmt
to
delete
the
power
control
group
setting.
After
deletion,
create
a
power
supply
interlocking
group
management
information
file
so
that
the
I/O
node
is
not
registered
with
multiple
groups,
and
then
use
setremotepwrmgmt
-c
config
to
register
it
again.
■
If
XCP
2080
or
earlier
is
used
together
with
a
single
SPARC
M10
system
that
is
connected
to
an
external
I/O
device,
do
not
use
the
power
supply
interlocking
function.
The
external
I/O
device
may
be
erroneously
powered
off
when
the
XSCF
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
26
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...