Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131213-011
x
When
a
SPARC
M10-4S
or
a
crossbar
box
is
added
using
the
addfru(8)
command,
the
following
message
is
output
and
the
addition
may
fail.
[Warning:036]
Failed
to
find
BB#x.
The
BB-ID
setting
and/or
the
cable
connections
of
the
BB#x
will
be
wrong.
Please
confirm
the
BB-ID
setting
and
the
cable
connections.
Do
you
want
to
try
to
add
BB#x
again?
[a:add|c:cancel]
:
When
the
following
maintenance
menu
is
output
after
executing
the
addfru(8)
command,
input
power
on
the
SPARC
M10-4S
or
the
crossbar
box
to
be
added
and
execute
the
next
operation
(step
2)
after
20
minutes.
Please
execute
the
following
steps:
1)
After
the
added
device
is
connected
with
the
system,
please
turn
on
the
breaker
of
the
BB#x.
2)
Please
select[f:finish]
:
[How
to
restore]
Input
"a"
in
response
to
the
"[a:add|c:
cancel]
:"
message
and
re-execute
the
addfru(8)
command.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
48
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...