Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
140227-004
x
x
x
If
a
link
card
is
removed
from
the
system
by
PCI
hot
plugging
(PHP),
using
the
cfgadm(1M)
command
on
the
logical
domain
on
which
it
is
mounted,
and
thus
power
supply
to
it
is
stopped,
the
"LINK
CARD
12C
error"
log
may
be
mistakenly
registered.
There
is
no
effective
workaround.
Ignore
this
error
log.
Power
supply
to
the
link
card
has
been
stopped
for
sure
and
the
system
can
be
operated
continuously.
RTIF2-
140227-005
x
At
the
time
of
cold
replacement
or
cold
addition
of
CPU
memory
unit
lower
(CMUL)
or
SPARC
M10
chassis,
if
the
following
conditions
are
met,
the
"XCP
firmware
version
synchronization
failed"
message
may
be
registered
to
the
event
log
and
maintenance
or
addition
fails.
-
Two
or
more
CMUL
or
SPARC
M10
chassis
is
cold
replaced
or
cold
added
at
one
time.
-
The
XCP
versions
of
replacement
components
do
not
match
the
version
of
the
master
XCP.
When
cold
replacing
or
cold
adding
two
or
more
CMUL
or
SPARC
M10
chassis,
use
the
replacefru(8)
or
addfru(8)
command
to
perform
the
operations
one
by
one.
[How
to
restore]
Execute
any
of
the
following
procedures.
-
Procedure
1
1.
Perform
AC
OFF/ON
2.
Execute
the
flashupdate(8)
command,
specifying
the
XCP
version.
XSCF>
flashupdate
-c
update
-m
xcp
-s
xxxx
-f
xxxx
is
the
XCP
version
of
the
master
XSCF
-
Procedure
2
Execute
the
replacefru(8)
command
to
perform
a
pseudo
replacement
of
the
CMUL
or
SPARC
M10
chassis
that
failed
to
be
cold
replace.
RTIF2-
140227-009
x
x
x
If
XSCF
login
is
performed
with
a
XSCF
user
account,
whose
privileges
are
managed
by
a
LDAP
server,
specified
by
the
setldap(8)
command,
execution
of
commands
in
the
XSCF
shell
or
operations
on
the
XSCF
Web
may
take
a
while.
In
case
of
a
LDAP
server,
specified
by
the
setldap(8)
command,
there
is
no
effective
workaround.
Specify
the
LDAP
server
with
the
setldapssl(8)
command.
RTIF2-
140227-010
x
The
following
improper
error
message
is
displayed
when
the
"addboard
-c
configure"
command
is
executed,
specifying
a
non-existent
system
board
(PSB):
PPAR
is
currently
unavailable
for
DR,
because
XBU
status
has
failed
Or
The
current
configuration
does
not
support
this
operation
There
is
no
effective
workaround.
Execute
the
"addboard
-c
configure"
command,
specifying
existent
PSBs.
RTIF2-
140304-001
x
When
performing
AC
OFF/ON,
in
some
very
rare
cases.
the
"SCF
process
down
detected"
error
message
is
registered
and
XSCF
fails
to
start.
There
is
no
effective
workaround.
If
this
symptom
has
occurred,
contact
the
maintenance
staff.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
54
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...