Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
140304-004
x
In
case
of
a
SPARC
M10-4S
that
is
attached
to
cross-bar
box,
if
XSCF
failure
occurs
on
a
portion
of
chassis
when
the
physical
partition
(PPAR)
is
in
the
powered
on
state,
the
follow
symptom
may
occur:
-
Symptom
1
When
the
poweroff(8)
command
is
executed,
the
power
on
the
PPAR
is
turned
off,
but
the
command
prompt
does
not
respond
for
about
20
minutes.
-
Symptom
2
When
the
PPAR
is
powered
on,
the
"XB-XB
interface
fatal
error"
error
is
produced,
the
power
on
process
is
repeated
and
it
does
not
end
properly.
If
XSCF
failure
has
occurred,
replace
the
CPU
memory
unit
lower
(CMUL)
or
the
XSCF
unit.
[How
to
restore]
-
Case
of
symptom
1
After
about
20
minutes,
the
poweroff(8)
command
ends
properly
and
the
prompt
comes
back.
-
Case
of
symptom
2
Forcibly
power
off
the
PPAR
using
the
"poweroff
-f"
command.
RTIF2-
140304-005
x
On
a
physical
partition
(PPAR)
that
is
composed
of
several
SPARC
M10-4S
(system
board)
,
after
a
system
board
has
been
degraded
due
to
failure,
if
the
setpciboxdio(8)
command
is
executed
to
disable/enable
the
direct
I/O
feature
of
the
PCI
card
mounted
on
the
PCI
expansion
unit
which
is
attached
to
the
degraded
chassis,
without
powering
off
the
PPAR
first,
the
following
message
is
output
and
the
command
fails:
"This
operation
cannot
be
done
because
the
PPAR
including
a
PSB
of
the
target
BB
is
powered
on"
This
symptom
occurs
when
the
state
of
system
board
is
like
the
following,
which
can
be
derive
from
either
the
showhardconf(8)
or
the
showboards(8)
command.
[Example]
When
PSB#01-0
(BB#01)
has
been
degraded.
XSCF>
showhardconf
...
*
BB#01
Status:Deconfigured;
...
XSCF>
showboards
-a
PSB
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
---
------------
-----------
----
----
----
-------
--------
01-0
00(01)
Assigned
n
n
n
Passed
Faulted
Change
the
configuration
of
the
direct
I/O
feature
with
the
setpciboxdio(8)
command
only
after
removing
the
degraded
system
board
from
the
physical
partition
with
the
deleteboard(8)
command.
[Example]
XSCF>
deleteboard
-c
unassign
01-0
After
changing
the
configuration
of
the
direct
I/O
feature,
assign
the
system
board
to
the
PPAR
with
the
addboard(8)
command
and
then
mount
the
system
board
onto
the
PPAR,
following
the
maintenance
procedure.
[Example]
XSCF>
addboard
-c
assign
-p
0
01-0
Meanwhile,
from
XCP
2210
onwards,
this
problem
can
be
solved
by
performing
maintenance
on
the
degraded
chassis
by
the
replacefru(8)
command.
In
such
a
case,
the
above
procedure
is
unnecessary.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
56
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...