Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
The
following
settings
are
excessively
restored
on
the
same
or
other
chassis.
-
Information
on
the
time
difference
between
XSCF
and
the
hypervisor
of
each
physical
partition
(PPAR)
The
following
settings
are
excessively
restored
on
other
chassis.
-
Setting
values
for
the
LDAP
client,
set
with
the
setldap(8)
command
-
Setting
values
for
the
LDAP
over
SSL
client,
set
with
the
setldapssl(8)
command
-
Configuration
setting
values
for
the
Active
Directory,
set
with
the
setad(8)
command
-
Setting
values
for
the
SNMP
agent,
set
with
the
setsnmp(8)/setsnmpusm(8)/
setsnmpvacm(8)
command
-
Setting
values
for
the
SMTP
service,
set
with
the
setsmtp(8)
command
-
Setting
values
for
the
notification
function,
set
with
the
setemailreport(8)
command
Furthermore,
since
the
PPAR
DR
feature
setting
values
cannot
be
saved/restored,
powering
on
the
PPAR
after
executing
the
following
procedure
switches
the
logical
domain
configuration
information
to
the
factory-default
state.
1.
Execute
the
setpparmode
-p
ppar_id
-m
ppar_dr
command
to
enable/disable
the
PPAR
DR
feature.
2.
Execute
the
dumpconfig(8)
command
to
save
XSCF
setting
information.
3.
Initialize
the
chassis
to
factory
defaults
by
executing
the
initbb(8)
or
the
restoredefaults(8)
command.
4.
Restore
the
XSCF
configuration
information
of
the
chassis
in
procedure
3
with
executing
the
restoreconfig(8)
command.
5.
Power
on
the
PPAR
by
executing
the
poweron(8)
command.
changes
[Example]
Saving
management
file
to
ftp
server
when
registering
one
power
supply
interlocking
group
XSCF>
getremotepwrmgmt
-G
1
ftp://server[:port]/path/file
Power
supply
interlocking
function
enable/disable
setting
[Example]
Enabled
XSCF>
showremotepwrmgmt
[Remote
Power
Management
Group#01
Information]
Remote
Power
Management
Status
:[Enable]
---
Omitted
---
-
Time
difference
between
XSCF
and
the
hypervisor
of
each
PPAR
[Example]
If
there
is
a
time
difference
between
XSCF
and
the
hypervisor
of
each
PPAR
XSCF>
showdateoffset
-a
PPAR-ID
Domain
Date
Offset
00
12
sec
01
12
sec
---
Omitted
---
15
12
sec
2.
Execute
the
dumpconfig(8)
command
to
save
the
XSCF
setting
information.
3.
If
the
XSCF
setting
information
is
to
be
restored
on
another
chassis,
execute
the
restoreconfig(8)
command
on
that
chassis
to
confirm
the
following
settings
before
restoring
the
XSCF
setting
information.
-
LDAP
client
setting
[Example]
To
display
all
LDAP
setting
information
except
the
CA
certificate
and
password
XSCF>
showldap
Bind
Name:
Not
set
Base
Distinguished
Name:
Not
set
LDAP
Search
Timeout:
60
Bind
Password:
Not
set
LDAP
Servers:
Not
set
CERTS:
None
Chapter
3
Information
on
Software
59
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...