Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
After
the
collection
is
complete,
turn
off/on
the
input
power
(AC
OFF/ON)
of
all
the
chassis
and
then
contact
the
maintenance
staff.
RTIF2-
140507-009
x
x
x
Even
when
rotation
abnormality
is
found
on
both
fans
at
the
same
time
in
the
same
fan
unit,
error
log
for
only
one
fan
is
registered
and
thus
the
system
is
not
shutdown.
As
a
result,
temperature
of
components
like
CPU
may
rise.
There
is
no
effective
workaround.
[How
to
Restore]
If
the
system
is
not
shut
down
when
fan
rotation
abnormality
is
detected,
if
any
of
the
following
symptom
is
confirmed
in
the
two
fans
which
comprises
the
faulty
fan
unit,
change
the
following
fan
unit
as
soon
as
possible:
-
The
"showenvironment
fan"
command
shows
that
the
number
of
rotation
has
been
decreased.
-
Visual
judgment
reveals
that
the
number
of
rotation
has
been
stopped.
RTIF2-
140507-
010
x
In
a
system
with
three
or
more
BBs
or
with
cross
boxes,
if
the
master/standby
switchover
if
executed
for
more
than
256
times,
the
"SCF
process
down
detected"
error
is
detected
on
the
slave
XSCF
and
XSCF
"coremgrd"
may
cause
process
down.
Do
not
perform
consecutive
XSCF
master/standby
switchover.
[How
to
Restore]
Reset
the
XSCF.
The
system
will
become
usable.
RTIF2-
140507-011
x
x
x
If
cold
replacement
of
CPU
memory
unit
lower
(CMUL)
or
a
motherboard
unit
(MBU)
is
done
in
the
following
procedure,
the
physical
partitions
(PPAR)
may
not
start.
1.
Execute
the
"restoredefaults
-c
factory"
command.
2.
After
XSCF
has
stopped,
turn
off
the
input
power
of
the
system
(AC
OFF).
3.
Replace
the
CMUL
or
MBU
without
replacing
the
microSD
card.
4.
Turn
on
the
input
power
of
the
system.
Replace
CMUL
or
MBU
in
the
following
procedure.
1.
Execute
the
"restoredefaults
-c
factory"
command.
2.
To
stop
XSCF
as
in
procedure
1,
turn
off/on
the
input
power
of
the
system
(AC
OFF/ON)
and
then
confirm
that
XSCF
has
started.
3.
Replace
the
targeted
CMUL
or
MBU.
[How
to
Restore]
Restore
with
the
following
procedure:
1.
Turn
off
the
input
power
of
the
system
(AC
OFF).
2.
Temporarily
mount
the
microSD
card
that
was
mounted
on
the
CMUL
or
MBU,
when
the
"restoredefaults
-c
factory"
command
was
executed,
to
the
new
unit.
3.
Confirm
that
XSCF
has
started
after
turning
on
the
input
power
(AC
ON).
4.
Turn
off
the
input
power
of
the
system
(AC
OFF).
5.
Extract
the
microSD
card
that
was
temporarily
mounted
and
mount
the
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
68
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...