Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
original
microSD
card.
6.
Turn
on
the
input
power
of
the
system
(AC
ON).
RTIF2-
140507-012
x
In
a
system
with
several
SPARC
M10-4S,
if
a
crossbar
box
or
the
XSCF
unit
of
a
crossbar
box
is
replaced
after
powering
off
all
chassis
and
then
the
input
power
is
turned
on,
the
following
error
log
may
be
registered.
Indispensable
parts
are
not
installed
(OPNL).
Indispensable
parts
are
not
installed
(FAN).
Indispensable
parts
are
not
installed
(PSU).
When
replacing
a
crossbar
box,
do
so
after
turning
off
the
input
power
(AC
OFF)
of
the
target
crossbar
box
only.
When
replacing
the
XSCF
unit
of
a
crossbar
box,
execute
the
replacefru(8)
command
to
do
so.
Refer
to
Fujitsu
M10-4/Fujitsu
M10-4S/
SPARC
M10-4/SPARC
M10-4S
Service
Manual
for
replacing
the
crossbar
box
or
the
XSCF
unit
in
the
crossbar
box.
[How
to
Restore]
Turn
off/on
the
input
power
(AC
OFF/ON)
of
the
replaced
crossbar
box.
RTIF2-
140507-014
x
When
replacefru(8),
addfru(8)
or,
rebootxscf(8)
command
is
executed,
the
"XSCF
hang-up
is
detected"
error
message
may
be
detected
at
the
slave
XSCF.
There
is
no
effective
workaround.
Ignore
this
error
log
as
the
command
in
question
is
terminated
properly
and
thus
it
has
no
effect
on
the
system.
RTIF2-
140507-016
x
After
configuring
the
XSCF
network
with
the
setnetwork(8)
command
and
applying
the
configuration
by
the
applynetwork(8)
command,
if
the
shownetwork(8)
command
is
executed
without
executing
the
rebootxscf(8)
command,
the
displayed
IP
address
may
not
match
the
IP
address
that
is
being
used
on
the
present
system.
After
executing
the
applynetwork(8)
command
to
apply
network
configurations
of
the
XSCF,
execute
the
rebootxscf(8)
command
to
reset
the
XSCF.
RTIF2-
140507-021
x
In
the
middle
of
performing
diagnosis
by
the
"-p"
and
"-b"
options
of
the
diagxbu(8)
command,
if
a
failure
occurs
in
the
physical
partition
specified
by
the
"-p"
option,
the
diagxbu(8)
command
may
terminate
abnormally
and
powering
off
the
SPARC
M10
chassis,
specified
by
the
"-b"
option
may
fail.
There
is
no
effective
workaround.
[How
to
Restore]
Perform
the
following
procedure:
1.
Turn
off
the
input
power
(AC
OFF)
of
SPARC
M10
chassis
using
the
"-b"
option
of
the
diagxbu(8)
command.
2.
Select
the
SPARC
M10
chassis
by
the
"-b"
option
of
the
replacefru(8)
command.
3.
When
the
message
for
the
replacement
of
SPARC
M10
chassis
is
output
in
the
maintenance
menu,
turn
on
the
input
power
(AC
ON)
of
the
SPARC
M10
chassis
without
replacing
it.
RTIF2-
140507-022
x
When
the
crossbar
cable
of
the
crossbar
unit
(XBU)
in
SPARC
M10-4S
is
in
bad
electrical
contact,
the
crossbar
cable
components
are
depicted
with
a
number
There
is
no
effective
workaround.
[How
to
Restore]
Perform
the
following
procedures:
1.
Power
off
the
physical
partition
Chapter
3
Information
on
Software
69
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...