Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
XSCF
in
a
SPARC
M10-4S
in
the
PPAR
resets
in
this
status,
you
may
be
unable
to
switch
to
the
control
domain
console.
You
can
confirm
that
this
event
has
occurred
by
executing
the
showlogs
event
command
and
confirming
that
an
event
log
for
console
path
switching
was
registered
during
the
time
between
POST
diagnosis
completion
and
OpenBoot
PROM
start
completion.
[Example]
Event
log
message
issued
when
PPAR_ID
is
0
POST
Diag
complete
from
PPAR
(PPAR
ID
0)
---
Omitted
---
PPAR
ID
0:
Console
path
is
switched
---
Omitted
---
PPARID
0
GID
00000000
state
change
(OpenBoot
Running)
RTIF2-
140605-002
x
Suppose
that
all
but
one
of
the
system
boards
(PSBs)
that
make
up
a
physical
partition
(PPAR)
are
faulty.
If
you
attempt
to
use
the
DR
function
to
disconnect
the
normal
PSB
by
executing
the
deleteboard(8)
command,
this
command
times
out
and
terminates
abnormally.
In
addition,
if
you
execute
the
deleteboard(8)
command
using
the
DR
function
after
then
in
an
attempt
to
disconnect
another
PSB
in
the
same
PPAR,
the
command
always
times
out.
Furthermore,
you
can
no
longer
connect
to
the
control
domain
console
by
executing
the
console(8)
command.
[Example]
deleteboard(8)
command
timeout
XSCF>
deleteboard
-c
disconnect
00-0
PSB#00-0
will
be
unconfigured
from
PPAR
immediately.
Continue?[y|n]
:
y
All
domains
are
temporarily
suspended,
proceed?[y|n]
:
y
Start
unconfigure
preparation
of
PSB.
[1200sec]
0.....
30.....
60.....
90.....120.....150.....180.....
210.....240.....\
270.....300.....330.....360.....390.....420.....450
.....480.....510.....\
If
all
but
one
of
the
PSBs
are
faulty,
first
turn
off
the
power
to
the
PPAR,
and
then
execute
the
deleteboard(8)
command
to
disconnect
the
normal
PSB.
[How
to
restore]
Execute
the
following
procedure:
1.
Execute
the
rebootxscf
-a
command
to
reset
the
XSCF.
2.
Check
the
error
logs
and
messages
to
identify
the
cause
of
the
error.
3.
Eliminate
the
cause
of
the
error.
4.
Perform
the
operation
described
in
"6.3.1
Example
operation
for
unassigning
a
system
board"
or
"6.3.3
Example
operation
for
reserving
the
unassignment
of
a
system
board"
in
the
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide
.
Chapter
3
Information
on
Software
71
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...