Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
4.
Execute
"setremotepwrmgmt
-c
enable"
to
enable
the
power
supply
interlocking.
(2)
Disable
the
power
supply
interlocking
function.
1.
Execute
"setremotepwrmgmt
-c
disable"
to
disable
the
power
supply
interlocking.
2.
If
the
external
I/O
device
is
ETERNUS,
set
the
ETERNUS
to
LOCAL
mode
for
operation.
RTIF2-
150129-001
x
[1]
If
the
input
voltage
drops,
usually
a
power
failure
notification
is
issued
and
the
power
of
the
physical
partition
is
turned
off.
However,
if
the
input
voltage
of
SPARC
M10-1
drops
instantaneously,
no
power
failure
notification
is
issued
and
the
power
of
the
physical
partition
is
turned
off.
[2]
If
you
execute
the
console(8)
command
to
switch
to
the
control
domain
console
and
input
texts
or
keys
during
the
physical
partition
power-off
due
to
the
trouble
in
[1],
the
following
error
log
may
be
detected
and
the
mother
board
unit
(MBU)
may
need
to
be
replaced.
MBC-CPU
interface
fatal
error
Check
all
the
following
five
conditions
are
satisfied
to
see
if
the
trouble
in
[1]
occurs.
-
Any
of
the
following
error
logs
is
registered.
-
MBU:SCF:failed
to
read/write
interrupt
mask
register
-
MBU:SCF:failed
to
read/write
active
status
register
-
Voltage
out
of
range
error
-
Oracle
Solaris
is
not
accessible
via
the
network.
-
No
power
failure
notification
is
issued.
(*1)
-
The
physical
partition
status
display
that
you
can
check
by
the
showpparstatus(8)
command
is
not
updated
and
indicates
the
physical
There
is
no
effective
workaround.
If
"MBC-CPU
interface
fatal
error"
is
detected,
replace
the
MBU.
If
"MBC-CPU
interface
fatal
error"
is
not
detected,
turn
off
the
input
power
supply
and
then
turn
it
on
again.
Chapter
3
Information
on
Software
81
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...