D.2.3.2
Brightness
-
M3096G: The brightness is specifiable in eight steps.
-
M3097G: The brightness is specifiable in 255 steps.
-
Note:
It is recommended to specify the values below to allow specification in eight
steps for both the M3096G and M3097G scanners.
01 (Brighter), 20, 40, 60, 80 (Medium), A0, C0, E0 (Darker)
D.2.3.3
Threshold
-
M3096G:
The value of threshold is specifiable in 64 steps. If the specified
value cannot be divided by 4, the fractional part (remainder) is
ignored.
-
M3097G:
The value of brightness is specifiable in 255 steps.
-
Note:
It is recommended to specify the values below to allow specification in 64 steps
for both the M3096G and M3097G scanners.
01 (Brighter), 04, 08, ... 80 (Medium), ....., FC (Darker)
D.2.3.4
Downloaded dither pattern and Brightness
-
M3096G:
To use the downloaded dither pattern in the M3096G scanner,
specify ™0∫ as Brightness.
-
M3097G:
If the downloaded dither pattern is used in the M3097G scanner,
the value of Brightness is specifiable in 255 steps.