M3099EX/EH OEM Manual
B-12
48 At Screen 30, press [Mode 1] until the digit
you want to change blinks. Then press [Mode
2] until the digit changes as you want. (The
specifiable range is from 1 to 1999 sec. in 1
sec. step.)
49 Press [Mode 1] and [Mode 2] at a time to see
Screen 29. The settings are stored to
EEPROM.
50 When you close the setup mode, go to 9 .
B3.16 Setting hopper time
When you set the hopper time, you must set as follows.
51 At Screen 2, press [Mode 1] sixteen times to
go to the HOPPER TIMER screen. (Screen
31)
52 Press [Mode 2] to see Screen 32. (The default
setting is 7 sec.)
53 At Screen 32, press [Mode 1] until the digit
you want to change blinks. Then press [Mode
2] until the digit changes as you want. (The
specifiable range is from 0 to 30 sec. in 1 sec.
step.)
54 Press [Mode 1] and [Mode 2] at a time to see
Screen 31. The settings are stored to
EEPROM.
55 When you close the setup mode, go to 9 .
<< SETUP MODE >>
HOPPER TIMER
HOPPER TIMER
X X
S
Screen 32
Screen 31