3-26
M3099EX/EH OEM Manual
Control register A#0
X'00' is set when the power is turned on or when a CLEAR
command is issued for initialization.
b7
b0
*1: When the start of reading is specified from the operator panel,
the Ready lamp lights at reception of a START command.
*2 If the manual mode is selected at the operator panel, reading
actually starts when a document is loaded on the scanner.
Scanning resolution
0
×××
: Set from the operator panel
1000:
400 dpi
1001:
300 dpi
1010:
240 dpi
1011:
200 dpi
1100:
1101:
1110:
1111:
Specified start of reading (*2)
0: Operation panel (*1)
1: Host computer
A#0
0
0
0
Not defined
Control register B#0
b7
b0
B#0
0
0
0
0
0
0
0
0