3-40
M3099EX/EH OEM Manual
Image control register A#1, B#1
X”00" is set when the power is turned on or when a CLEAR
command is issued for initialization.
0
0
0
b7
b0
#1
Automatic separation specification (*1)
0 x : Set from the operator panel (*2)
1 0 : Automatic separation is not done.
1 1 : Automatic speparation
Conversion mode specification
0 x x : Not operation
1 0 0 : Not provided with white/black conversion.
Not provided with right/left conversion.
1 0 1 : Not provided with white/black conversion.
Provided with right/left conversion.
1 1 0 : Provided with white/black conversion.
Not provided with right/left conversion.
1 1 1 : Provided with white/black conversion.
Provided with right/left conversion.
Note: Image control registers #1 to #3 must be sent in one sequence.
One of automatic separation, image emphasis, outline extract,
overlay can be specified.
*1: Halftone specification (control register #2) is invalid in the
automatic separation mode. However, halftone processing
(dither or error diffusion) for photo area follows control register
#19, and the dither pattern follows control register #2.
*2: When automatic separation specification is based on operator
panel, the bit 7 of image control register #2 and the bit 3 of
image control register #3 must be set to '0'.
Summary of Contents for M3099EH
Page 1: ...M3099EX EH IMAGE SCANNER OEM MANUAL C150 E047 02EN ...
Page 2: ...M3099EX EH IMAGE SCANNER OEM MANUAL ...
Page 15: ...M3099EX EH OEM Manual 1 3 OVERVIEW Figure 1 2 1000 sheets hopper type ...
Page 170: ...4 40 M3099EX EH OEM Manual ...
Page 176: ...5 6 M3099EX EH OEM Manual ...
Page 196: ...8 10 M3099EX EH OEM Manual ...
Page 216: ...M3099EX EH OEM Manual B 14 ...
Page 226: ...IN 4 M3099EX EH OEM Manual ...
Page 228: ......