5.5 Checking Operation after Installation and Preparing the IDD for Use
C141-E133-02EN
5-13
5.
The saved value of the MODE SELECT parameter is assumed as the initial
value of each parameter after the power-on, the RESET condition, or the
BUS DEVICE RESET message. The INIT can change the parameter value
temporary (actively) at any timing by issuing the MODE SELECT or
MODE SELECT EXTENDED command with specifying "0" to the SP bit in
the CDB.
(1)
Error recovery parameter
The following parameters are used to control operations such as IDD internal error recovery:
a.
Read/write error recovery parameters (page code = 1)
Parameter
Default value
• AWRE:
• ARRE:
• TB:
• EER:
• PER:
• DCR:
Automatic alternate block allocation at Write
operation
Automatic alternate block allocation at read
operation
Uncorrectable data transfer to the INIT
Immediate correction of correctable error
Report of recovered error
Suppression of ECC error correction
1 (enabled)
1 (enabled)
1 (enabled)
1 (enabled)
0 (disabled)
0 (Correction is
enabled.)
• Retry count at read operation
• Retry count at write operation
• Recovery time limit
63
63
30 sec
b. Verify error recovery parameters (page code = 7)
Parameter
Default value
• ERR:
• PER:
• DTE:
• DCR:
Immediate correction of recoverable error
Report of recovered error
Stop of command processing at successful
error recovery
Suppression of ECC error correction
1 (enabled)
0 (disabled)
0 (Processing is
continued.)
0 (Correction is
enabled.)
• Retry count at verification
63
c.
Additional error recovery parameters (page code = 21)
Parameter
Default value
• Retry count at seek error
15
Summary of Contents for MAN3367FC - Enterprise 36.7 GB Hard Drive
Page 1: ...C141 E133 02EN MAN3735FC SERIES MAN3367FC SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ......
Page 6: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 21: ...Contents C141 E133 02EN xv Glossary GL 1 Abbreviations AB 1 Index IN 1 ...
Page 24: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 66: ...Installation Requirements 4 10 C141 E133 02EN Figure 4 10 SCA2 type connector ...
Page 110: ...Principle of Operation 8 8 C141 E133 02EN Figure 8 3 Block diagram of read write circuit ...
Page 116: ...This page is intentionally left blank ...
Page 132: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 144: ...This page is intentionally left blank ...
Page 146: ...This page is intentionally left blank ...
Page 147: ......
Page 148: ......