Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3
cm from the disk drive. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature does not exceed 60°C.
•
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.
Table 4.1
Surface temperature check point
No.
Measurement point
Criteria
1
Center of DE cover
60°C
2
Read channel LSI
88°C
3
VCM/SPM Driver
92°C
4
HDC
91°C
5
MPU
91°C
1
4
5
2
3
Figure 4.6 Surface temperature measurement points
(5)
Service clearance area
The service clearance area, or the sides which must allow access to the IDD for installation or
maintenance, is shown in Figures 4.7.
Summary of Contents for MAP3147NC - Enterprise - Hard Drive
Page 1: ...C141 E166 01EN MAP3147NC NP MAP3735NC NP MAP3367NC NP DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 10: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 66: ...4 14 C141 E166 Figure 4 17 External operator panel connector CN2 ...
Page 122: ...This page is intentionally left blank ...
Page 126: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 130: ...This page is intentionally left blank ...
Page 131: ......
Page 132: ......