5
1.3 General Specifications
1.3
General Specifications
Table 1.3-1 "General Specifications of Emulator" lists the general specifications of the
emulator.
■
General Specifications of Emulator
Use the product according to its specifications. Doing so may result in
device problems.
CAUTION
Caution
Table 1.3-1 General Specifications of Emulator
Item
Specification
Name
DSU-FR emulator
Model number
MB2198-01
Power
Emulator power input
+16 V / 2.5 A (supplied from the dedicated
AC adapter)
DSU-dedicated power output(*1)
+3.3 V (V
CC
T) / 350 mA (with fuse)
User system power input(*2)
0 V to +5.5 V (UV
CC
) / 100 mA or less
Operating frequency
Maximum of 33 MHz(*3)
Operating temperature
5 to 35
Operating humidity
20% to 80% (No condensation)
External dimensions
148 (W) x 210 (D) x 44 (H) mm (not including protrusions and rubber pads)
Weight
700 g
*1 Use this only if the evaluation MCU has a DSU-dedicated power input terminal.
Do not use this terminal for any other purpose.
The emulator supplies power through a DSU-FR cable or adapter board to the evaluation MCU.
*2 The user system power must be supplied from the user system through a DSU-FR cable or adapter board.
*3 Note that this is the operating frequency of the emulator interface bus and not that of the MCU. The
minimum operating frequency depends on the debugger software.
Summary of Contents for MB2147-01
Page 10: ......
Page 11: ...FUJITSU LIMITED DSU FR EMULATOR MB2198 01 HARDWARE MANUAL ...
Page 12: ......
Page 20: ...viii ...
Page 22: ...x ...
Page 56: ...34 CHAPTER 2 CONNECTION METHOD ...
Page 64: ...42 CHAPTER 3 OPERATION METHOD ...
Page 66: ......
Page 76: ...54 APPENDIX B User System Specifications ...
Page 78: ......
Page 92: ......